10-1
SECTION 10
Testing the System
•••••••••••••••••••••••••••••••••••••••••••••••••
Battery Test
When AC power is present, the VISTA-128BP/VISTA-
250BP runs a brief battery test every 60 seconds to
determine if there is a battery connected, and runs an
extended battery test every 4 hours to check on the
batterys condition.
If the VISTA-128BP/VISTA-250BP finds that the
battery voltage is low (less than approximately 11.5V),
it initiates a keypad SYSTEM LOBAT display and a
rapid keypad beeping sound. It also sends a Low
Battery report to the central station (if programmed).
The keypad is cleared by entering any security code +
OFF, and a Restore report is sent to the central station
if the situation has been corrected.
Dialer Test
The VISTA-128BP/VISTA-250BP may be programmed
to automatically transmit test reports to a central
station at intervals ranging from once per hour to once
per 9999 hours (field
27).
UL requires the test report to be transmitted at least
once every 24 hours. The system can be programmed to
send the first report at any time of the day, or on any
day of the week (field
83).
Burglary Walk-Test (Code + [5] TEST)
This test causes the system to sound keypad beeps in
response to faults on zones for the purpose of allowing
proper zone operation to be checked without triggering
alarms. This test can be activated by any-level user by
entering the corresponding security code and pressing
TEST while the burglary portion of the system is
disarmed. UL requires that this test be conducted on a
weekly basis.
When this test is first entered, the system activates the
alarm output for 3 seconds. The system sends a Start
of Walk-Test message to the central station. The
keypad displays Burg Walk Test in Progress and
sounds a single beep every 15 seconds while the test
remains active.
Open and close each protected door and window in
turn. Each action should produce 3 beeps from the
keypad. Walk in front of any motion detectors. Listen
for three beeps when the detector senses movement.
The keypad displays the zone number and alpha
descriptor while a door or window remains open or
while a detector remains activated. The system
automatically issues a Zone 8 Glassbreak Detector
Power Reset about 10 seconds after it finds a fault on
this zone, to allow faulted detectors to be reset.
To end this test, enter any security code and press OFF.
An End of Walk-Test message is sent to the central
station.
Armed Burglary System Test
Alarm messages are sent to the central
station during the armed system tests.
Notify the central station that a test will be
in progress.
A display of COMM. FAILURE indicates
a failure to communicate (no kissoff by the
receiver at the central station after the
maximum number of transmission
attempts is tried). If this occurs, verify that
the phone line is connected, the correct
report format is programmed, etc.
To perform an armed burglary test, proceed as follows:
Step Action
1 Notify the central station that a test of the
system is being performed.
2 Arm the system.
3 Fault one or more zones.
4 Silence alarm sounder(s) each time by
entering the code and pressing OFF.
NOTE:
The system must be rearmed after
each code + off sequence.