Section 5 Data Field Descriptions
5-13
FIELD
TITLE and DATA ENTRIES EXPLANATION
2*09
Open/Close Reports by
Exception (partition-specific)
0
= disable
1
= enable
If enabled, Open/Close reports are sent
only if
the openings/closings
occur
outside
the arm and disarm windows.
NOTES:
Open reports are also suppressed during the closing window in order to
prevent false alarms if the user arms the system, then re-enters the
premises, for example to retrieve a forgotten item.
Openings and closings are still recorded in the event log.
This field
must
be set to
1
if No Opening and No Closing reports are to be
sent.
2*10
Allow Disarming Only During
Arm/Disarm Windows (partition-
specific)
0
= disable
1
= enable
If enabled, disarming of the system is allowed only during the
arming/disarming windows, or if the system is in alarm (if 2*11 is set to
1).
NOTE:
This applies
only
to Operator-level users. Installer, Master, and
Manager-level users can disarm the system at any time.
2*11
Allow Disarm Outside Window if
Alarm Occurs
0
= disable
1
= enable
If enabled, allows the system to be disarmed outside the programmed
disarm (opening) window if an alarm has occurred. Otherwise disarming
is allowed only during the disarm window.
NOTE:
Used only if field 2*10 is enabled.
2*18
Enable GOTO for this Partition
(partition-specific)
0
= disable
1
= enable
If enabled, this partition can be accessed from another partitions keypad
using the GOTO command.
2*19
Use Partition Descriptor
0
= disable
1
= enable
If enabled, the normal keypad display will include a partition number and
four-digit descriptor.
2*20
Enable J7 Triggers for Partition
(partition-specific)
0
= disable
1
= enable
If enabled, the J7 triggers function for this partition.
2*21
Supervision Pulses for LRR
0
= disable
1
= enable
There are three entries in this field as follows: Fire, Burglary/Audible
Panic, Silent Panic/Duress.
If enabled, causes the control to send periodic short pulses on the J7 radio
triggers to the LRR. The LRR uses these pulses to determine that its
connection to the control is still intact.
Must be
1
for UL installations.
2*22
Display Fire Alarms of Other
Partitions (partition-specific)
0
= disable
1
= enable
If enabled, allows fire alarms that occur on other partitions to be
displayed at this partitions keypad(s).
2*23
Display Burglary & Panic Alarms
for Other Partitions (partition-
specific)
0
= disable
1
= enable
If enabled, allows burglary and panic alarms that occur on other
partitions to be displayed at this partitions keypad(s).
2*24
Display Troubles of Other
Partitions (partition-specific)
0
= disable
1
= enable
If enabled, allows troubles that occur on other partitions to be displayed
at this partitions keypad(s).