VISTA-128BP/VISTA-250BP Installation and Setup Guide
5-10
FIELD
TITLE and DATA ENTRIES EXPLANATION
1*33
TouchTone with Rotary Backup
0
= disable
1
= enable
If enabled, the system reverts to rotary dialing if communicator is not
successful in dialing using TouchTone DTMF on first attempt.
1*34
Communicator Split Reporting
0
= Split Reporting disabled
1
= Alarm, Alarm Restore, and Cancel
reports to primary, all others to secondary
2
= Open/Close and Test reports to
secondary, all other reports to primary
Select the type of split reporting for system communication.
NOTE:
See *51 for split/dual reporting combinations.
1*35
Access Control Dialer Enables
0
= disable
1
= enable
There are six entries for this field as follows: Trace, Trouble, Not Used,
Bypass, System, Alarm.
If Trace is enabled, access grant/denial events sent to the central station.
For the other events, if enabled, a report is sent to the central station.
1*42
Call Waiting Defeat
0
= disable
1
= enable
If enabled, the system defeats Call Waiting on the first outgoing call
attempt to both the primary and secondary numbers.
NOTES:
After the panel's initial call to report the alarm, the panel may attempt to
make an additional call, perhaps for a cancel or a zone restoral. If Call
Waiting is not defeated, an operator at the central station attempting to
contact the premises (to verify whether the alarm is valid) hears the
phone ringing indefinitely and must to dispatch on the call.
DO NOT enable this feature unless Call Waiting is being used.
1*43
Permanent Keypad Display
Backlighting (partition-specific)
0
= disable
1
= enable
If enabled, backlighting for the keypad display remains on at all times.
Otherwise the backlighting comes on when a key is pressed.
NOTE:
When a key is pressed, display backlighting turns on for
all
keypads in that partition.
1*44
Wireless Keypad Tamper Detect
0
= disable
1
= enable
If enabled, when more than 40 key depressions are received without a
valid sequence (arm, disarm, etc.), the control panel disables the wireless
keypad. The inhibit is removed once a valid key sequence is received from
a wired keypad.
1*45
Exit Delay Sounding (partition-
specific)
0
= disable
1
= enable
If enabled, the system produces slow beeping from the keypads during
exit delay and reverts to rapid beeping during the last 10 seconds of the
exit delay.
NOTE:
The duration of the beeping is the programmed value of field *10
regardless of which entry/exit zone is used to exit the premises.
1*46
Auxiliary Output Mode
0
= ground start output.
1
= smoke detector reset.
2
= keypad sounds at an auxiliary sounder.
3
= AAV module.
Select the mode for output 1 on the J7 triggers.
NOTES:
Only one of the options may be active within the system.
Option 2 is available in the VISTA-128BP only.
Option 2 applies only to the partition enabled in field *15.
1*47
Chime on External Siren
(partition-specific)
0
= disable
1
= enable
If enabled, the system produces chime annunciation on the external
alarm sounder.
1*48
Wireless Keypad Assignment
0
= none
1-8
= partition number
Select the partition in which RF keypad is used.