SECTION 1
General Description
••••••••••••••••••••••••••••••••••••••••••••••••••
About the VISTA-128BP/VISTA-250BP
The VISTA-128BP/VISTA-250BP is an 8-partition, UL Listed control panel with the following features:
Up to 128 zones for VISTA-128BP; 250 zones for VISTA-250BP (hardwired, polling loop, and wireless zones)
Up to 150 user codes for VISTA-128BP; 250 user codes for VISTA-250BP
Supervision of bells, keypads, RF receivers, and output devices
Scheduling capabilities (allows certain operations to be automated)
The capability to link up to 8 control panels using Panel Linking Modules
The VISTA-128BP/VISTA-250BP can interface with the following devices:
TeleSmart (See the TeleSmart instructions for operating procedures)
An alpha numeric paging device (VA8201)
Symphony (AUI)
Panel Link Module (VA8200)
An ECP Long Range Radio that can send Contact ID messages
An access control system by using either the ADEMCO PassPoint system (via the VISTA Gateway Module) or a
VistaKey module (via the polling loop)
U
L
The access control function is not Listed for use with the VISTA-128BP/VISTA-250BP Control Panel in a UL
installation.
The system supports either the VistaKey or the VISTA Gateway Module, not both.
NOTE: All references in this manual for number of zones, number of user codes, number of access cards,
and the event log capacity, use the VISTA-250BP’s features. The following table lists the differences
between the VISTA-128BP and the VISTA-250BP control panels. All other features are identical, except for
the Remote Keypad Sounder (field 1
46 option 2), which is available only in the VISTA128BP.
Feature VISTA-128BP VISTA-250BP
Number of Zones 128 250
Number of User Codes 150 250
Number of Access Cards 250 500
Event Log Capacity 512 1000
Features
Hardwire and Optional Expansion Zones
Provides 9 hardwire zones.
Supports up to 16 2-wire smoke detectors on zone 1.
Automatically resets 4-wire smoke detectors using the J7 output when a code + off is entered.
Triggers the built-in sounders on other hardwired smoke detectors if one smoke detector annunciates an alarm.
This feature requires a 4204 Relay Module and/or the 333PRM.
Provides tamper supervision on the hardwire zones.