Section 3 - Installing the Control
3-21
Alphanumeric
PP Date Time EA ZZZ SSSS AD
Where:
PP Partition number (e.g., P1)
Date Date the event occurred (e.g., 03/15/00)
Time Time the event occurred (e.g., 01:16AM)
EA Event alpha descriptor (see
APPENDIX D
)
ZZZ Zone or user number
SSSS The partition’s 4-digit subscriber number
(in field
✳
32)
AD The zone’s programmed alpha descriptor
✳
✳
If the event is an arming or disarming, a 6-
character descriptor can be sent for the user, if
programmed, instead of the user number. The
descriptor can be programmed only via the
Compass Downloader.
The installer code has a default of INSTLR and
user number 002 has a default of MASTER for
the 6-character descriptor.
Mounting the Alpha Pager Module
The Alpha Pager Module (APM) may be mounted in the
control cabinet if space is available or, if this is not
possible, on the side of the cabinet or adjacent to it.
Do not mount the Alpha Pager Module on the
cabinet door or attempt to attach it to the PC
board.
To mount the Alpha Pager Module, perform the
following steps:
Step Action
1 If you are mounting the Alpha Pager
Module inside the control cabinet, attach it
to the cabinet’s interior surface with 2-faced
adhesive tape.
2 If you are mounting the Alpha Pager
Module outside the cabinet, use the bracket
interface (Ademco Part Number K5350).
Wiring the Alpha Pager Module
The Alpha Pager Module connects via the 4142TR cable
to the J8 connector on the VISTA-128BP/VISTA-250BP.
To wire the Alpha Pager Module, refer to
Figure 3-30
and perform the following steps:
Step Action
1 Connect the 4142TR to J8 on the control.
2 Connect the Brown wire of 4142TR to the
Orange wire of the APM.
3 Connect the Green wire of the APM to TB1-
23 of the control panel.
4 Connect the Red and Black wires of the APM
to terminals 6 and 7 (auxiliary power (+) and
(-), respectively) of the control.
5 Connect the APM RJ11 connector labeled
LINE to the handset terminals on the control
panel (terminals 26 and 27).
6 Connect the handset side of telephone line to
APM RJ11 connector labeled PHONE
(Optional) (Brown and Gray wires of Phone
Cord).
7 If you are using a parallel or serial printer,
connect the printer according to the
instructions accompanying the APM
.
•
The serial printer must be configured for a
baud rate of 1200, seven data bits, even parity,
and one stop bit. (7/E/1).
•
Automation software cannot be used if a serial
printer is used on the system.
VA8201 ALPHA PAGER MODULE
AUX
PWR.
PARALLEL
PRINTER
PARALLEL
OUTPUT
SERIAL
OUTPUT
DATA /
POWER
TO PHONE
TO LINE
EARTH
GROUND
HOME AUTOMATION COMPUTER
TIP
RING
RJ31X
JACK
TIP
RING
INCOMING TELCO LINE
ANSWERING
MACHINE
CALLER ID
UNIT
PREMISES
CALLER ID UNIT,
ANSWERING
MACHINE, AND
PHONES
RED
BROWN
GRAY
GREEN
RED
BLACK
GREEN
RED
BLACK
GREEN
AUX
GND.
62627282930237
TIP RING
HANDSET
TIP RING
INCOMING
PHONE
CORD
(ZONE 9)
BROWN WIRE
FROM 4142 TR
TRIGGER CABLE
SPLICE
VA8201-SOC-V1
1 2 3 4 5 6 7 8 9
J8
BROWN
ORANGE
CONTROL PANEL
NOTE
WHEN USING THE VA8201, ZONE 9 CAN NO
LONGER BE USED AS A PROTECTION ZONE.
Figure 3-30: Wiring the Alpha Pager Module
Comentarios a estos manuales