VISTA-128BP/VISTA-250BP Installation and Setup Guide
1-2
•
Supports up to 50 2-wire latching glassbreak detectors on zone 8.
•
Supports up to 241 additional expansion zones (119 for the VISTA-128BP) using a built-in polling (multiplex) loop.
•
Supports up to 250 wireless zones (128 for the VISTA-128BP) (fewer if using hardwire and/or polling loop zones).
U
L
The 5881ENHC RF Receiver and the 5869 Holdup Switch Transmitter are listed for UL Commercial Burglary
applications. All other RF receivers and transmitters are not listed for UL Commercial Burglary applications.
•
Can program burglary zones as silent in the alarm condition (alarm output is silent and the keypad does not display
or sound the alarm).
•
Provides three keypad panic keys: 1 + ✴ (A), ✴ + # (B), and 3 + # (C).
Peripherals Devices
•
Supports up to 31 addressable devices, (keypads, RF receivers, relay modules, etc.).
•
Supervises devices (keypads, RF receivers, and relay modules) and individual relays (up to 32), as well as system
zones (RF receivers and keypad panics).
•
Provides 96 outputs using 4204 and 4204CF Relay Modules, Fire System Annunciators (FSA-8, FSA-24), V-Plex
Relay Modules and Powerline Carrier Devices (X-10) can activate outputs in response to system events (alarm
condition), at a specific time of day, at random times, and manually using the #70 Relay Command Mode.
•
Supports the ADEMCO 4285/4286 VIP Module, which allows access to the system from either a remote location or
on the premises
U
L
The VIP Module is not Listed for use with the VISTA-128BP/VISTA-250BP Control Panel in a UL installation.
•
Supports the ADEMCO 4146 Keyswitch on any one of the system's 8 partitions.
Arming/Disarming and Bypassing
•
Can arm the system with zones faulted (Vent Zone). These zones are automatically bypassed and can be
programmed to automatically unbypass when the zone restores.
•
Can arm with entry/exit and interior type zones faulted (Arm w/Fault). These zones must be restored before the exit
delay expires, otherwise an alarm is generated.
•
Provides global arming capability (ability to arm all partitions the user code has access to in one command).
•
Can Quick Exit an armed premises without having to disarm and then rearm the system.
•
Can be armed in one of three STAY modes or Instant modes, automatically bypassing specific burglary zones
regardless of the zone response type.
•
Can automatically bypass specific zones if no one exits the premises after arming (Auto-STAY). Auto-STAY will not
occur if the system is armed via an RF transmitter, VIP module, scheduling, access control, keyswitch, RS232
automation or downloading.
•
Can bypass a group of zones with one set of keystrokes.
•
Supports Exit Error Logic, whereby the system can tell the difference between a regular alarm and an alarm caused
by leaving an entry/exit door open. If the system is not subsequently disarmed, faulted E/E zone(s) and/or interior
zones are bypassed and the system arms.
•
Supports Recent Close report, which is designed to notify the central station that an alarm has occurred within 2
minutes after the exit delay has expired.
Partitioning and Panel Linking
•
Can control 8 separate areas independently, each functioning as if it had its own separate control.
•
Provides a Common Lobby partition, which can be programmed to arm automatically when the last partition is
armed, and to disarm when the first partition is disarmed.
•
Provides a Master partition (9), used for the purpose of viewing the status of all partitions at the same time.
•
Can display fire, burglary, panic and trouble conditions at all other partitions’ keypads (selectable option).
•
Can “link” together up to 8 control panels. This allows users to access and control from a keypad another control
panel.