VISTA-128BP/VISTA-250BP Installation and Setup Guide
5-4
FIELD
TITLE and DATA ENTRIES EXPLANATION
*32
Primary Subscriber’s Account
Number (partition-specific)
Enter
00-09; B-F (11-15)
Enter a 3- or 4-digit (depending on report format) primary subscriber
account number. Each number requires a 2-digit entry so as to allow
entry of hexadecimal digits (B-F). If a 3-digit account number is to be
used, enter data only in the first 3 locations, and enter * in the fourth
location.
*33
Primary Phone Number
Enter
0-9; #11
for *
, #12
for
#, #13
for
a 2-
second pause.
Enter the primary central station phone number, up to 17 digits. This is
the phone number the control will use to transmit Alarm and status
messages to the central station. Do not fill unused spaces.
NOTE:
Backup reporting is automatic only if a secondary phone number
is entered.
*34
Secondary Phone Number
Enter
0-9; #11
for *
, #12
for
#, #13
for
a 2-
second pause.
Enter the secondary phone number, up to 17 digits. The secondary phone
number
is used if communication on the primary number is unsuccessful,
or if split/dual reporting is desired. Do not fill unused spaces.
NOTE:
If this field is programmed, a secondary subscriber account
number (field *90)
must
also be programmed.
*35
Download Phone Number
Enter
0-9; #11
for *
, #12
for
#, #13
for
a 2-
second pause.
Enter the downloading phone number, up to 17 digits. Do not fill unused
spaces.
NOTE:
This field is applicable only if downloading is utilized.
*36
Download ID Number
Make entries as 2-digit numbers as follows:
00=0 01=1 02=2 03=3 04=4 05=5
06=6 07=7 08=8 09=9 10=A 11=B
12=C 13=D 14=E 15=F
Enter eight digits.
NOTE:
This field is applicable only if downloading is utilized.
*37
Download Command Enables
0
= disable
1
= enable
Enabling a function means that you are able to perform that function via
the ADEMCO Compass Downloading software.
Functions are as follows: Dialer Shutdown; System Shutdown; Not Used;
Remote Bypass; Remote Disarm; Remote Arm; Upload Program;
Download Program.
For UL installations, all entries must be
0
.
*38
Prevent Zone XXX Bypass
(partition-specific)
Enter a zone number
(001-250)
.
Enter
000
if all zones can be bypassed.
Enter three digits for zone that cannot be bypassed by the user.
NOTES:
The actions manual bypass, group bypass, auto-stay, and STAY/INSTANT
arming modes cannot bypass any zone programmed in this field.
The system will not arm if the zone is programmed with the vent zone or
force arm fault attributes.
*39
Enable Open/Close Report for
Installer Code (partition-specific)
0
= disable
1
= enable
If enabled, whenever the Installer Code is used to arm or disarm the
partition, an open/close report is sent to the central station.
*40
Enable Open/Close report for
Keyswitch
0
= disable
1
= enable
If enabled, whenever the keyswitch is used to arm or disarm the partition,
an open/close report is sent to the central station.
*41
Normally Closed or EOLR (Zones
2-8)
0
= disable
1
= enable
If disabled, end-of-line resistors must be used on zones 2-8.
If enabled end-of-line resistors cannot be used and only
normally closed
devices must be used.
Must be
0
for UL installations.