Section 5 Data Field Descriptions
5-11
FIELD
TITLE and DATA ENTRIES EXPLANATION
1*49
Suppress Transmitter
Supervision Sound
0
= disable
1
= enable
If enabled, no trouble soundings occur on the keypad for transmitter
check-in failures.
Must be
0
for UL.
1*52
Send Cancel If Alarm + Off
(partition-specific)
0
= disable
1
= enable
If enabled, Cancel reports are sent when the system is disarmed after an
alarm, regardless of how much time has gone by.
If disabled, Cancel reports are sent within Bell Timeout period only.
1*53
Disable Download Callback
0
= callback required
1
= no callback required
Select whether a callback from the control panel is required for
downloading.
Must be
0
for UL installations.
1*55
International Date Format
0
= disable (mm/dd/yy)
1
= enable (dd/mm/yy)
Select the date format for display in the event log.
1*56
AC 60Hz or 50Hz
0
= 60Hz
1
= 50Hz
Select the frequency for the AC.
Must be set to
0
for U.S. and Canadian installations.
1*57
Enable 5800 RF Button Global
Arm
0
= disable
1
= enable
If enabled, the system arms/disarms in accordance with the buttons
users global arming settings.
1*58
Enable 5800 RF Button Force
Arm
0
= disable
1
= enable
If enabled, allows the RF button user to force a bypass of all faulted zones
when arming the system.
NOTE:
When attempting to arm the system, the keypad beeps once after
the button is pressed if any faulted zones are present. The user should
then press the button again within 4 seconds to force-bypass those zones
and arm the system.
1*60
Zone 5 Audio Alarm Verification
0
= disable
1
= enable
If enabled, zone 5 is used for 2-way audio (AAV).
Must be 0 for UL installations.
NOTE:
Zone 5 cannot be used as protection zone.
1*69
Printer Type
0
= parallel printer
1
= serial printer
Select the printer type for the event log printout.
NOTE:
if you are using a parallel printer connected to the VA8201 Alpha
Pager Module.
1*70
Event Log Types
0
= disable
1
= enable
This field has five entries as follows: Alarm, Check, Bypass, Open/Close,
System. If enabled, the system logs those events into the event log.
NOTE:
Events are also logged into the PassPoint system, if installed.
1*71
12/24 Hour Type Stamp Format
0
= 12-hour
1
= 24-hour
Select the type of time stamping for the event log.
1*72
Event Log Printer On-Line Mode
0
= disable
1
= enable
If enabled, the system prints the events as they occur.
If disabled, the system prints the log only upon request.
1*73
Printer Baud Rate
0
= 1200
1
= 300
Select the baud rate for the serial printer.
NOTE:
Must be
1
if using the alphanumeric pager interface.