ADEMCO VISTA-120 Guia de preparacion Pagina 51

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 53
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 50
Vista 120 Training Guide 51
6.9 Garage Door Setup
Training Module
Learn in zone required to trigger the relay driving the garage or roller door.
Go to #93 and select “Device Programming”. Program the relay module address as set on
its dip switches.
Exit “device Programming”.
Select “Relay Programming”.
Select the relay number you wish to program to pulse to garage door motor
Select the “Action” Closed for 2 seconds.
Select the start event Fault, followed by the zone list that you wish to assign the zone
from the 5804 to.
Select the partition that the start function will occur in.
No “Stop” programming is required as the relay is closed for 2 seconds
No further programming is required in relay programming.
After all relays have been programmed, upon entering “00” at the “ENTER RELAY NO”
prompt, you will be asked to enter a “Zone List”. If a zone list number was used to start or
stop relay, you must define the zone that belongs to that zone list as follows:
Enter “Zone List” number assigned to trigger the door relay.
Enter 2 digit entries followed by * for all zones that will be used to open the door. Finish
with 00*.
Enter 2 digit entries followed by * for all zones that will be used to open the door. Finish
with 00*.
Make sure that the 5804 has been assigned to a user.
Exit program mode.
Code + off the system.
Vista de pagina 50