Vista 120 Training Guide 33
ZONE PROGRAMMING:
ZONE DEFINITIONS FOR ZONES 1-24
DIP DIP † Enter loop number on module Must be 1
Parti- RF Trans. Type
†
RPM RPM for basic wired, serial numbered, and DIP left loop
devices
Zone Zone tion RF UR BR left right Ser. Basic Report Zone Information (part numbers) &
No. Type (1-8) (3) (4) (5) loop loop RPM
†
Wired Code Alpha Descriptor (3 words max.)
1
2
3
4
5
6
7
8
9
• Remain in #93 Menu mode
• Answer No “0” until Zone Programming Option is selected
• Answer Yes “1” to Zone Programming
• Enter 3 digit Zone Number (001 – 128)
• Press * to move to Zone Summary
ZT = Zone Type
P = Partition
RC = Report Code
In = Input Type
L = Response Time or
Loop Number
• Press * to move to Zone Response Type
• Enter required Zone Type
ON IN STAY MODE OFF IN STAY MODE 24 HOUR ZONE
Type 01 Entry / Exit Burglary #1 Type 04 Interior Follower Type 05 Trouble Day/Alarm Night
Type 02 Entry / Exit Burglary #2 Type 10 Interior with Delay Type 06 24 Hour Silent Alarm
Type 03 Perimeter Burglary Type 07 24 Hour Audible Alarm
Type 08 24-Hour Auxiliary Alarm
Type 09 Supervised Fire
Type 19 24-Hour Trouble
09 1 00 HW: 1