6.3 5804 Four Button Remote
Training Module
Each Button is a separate zone. (Max 4 Zones per Remote)
It is advisable to mark the Key with the first zone number, so they can be identified when
required
To avoid “check” conditions, Loop 4 must be programmed into the system
Install & program 5882 Wireless receiver(s) as per 5882 Instructions
Enter program mode. (Installer code + 8 + 000)
Go to #93 and select “Enter Zone programming”
Select an unused zone from 010-128
Program zone type as required (eg. 20= arm stay, 21= arm away, 22= disarm)
Select partition and report code for remote key
Select input type 5 (Button RF)
Learn loop button being used on that particular zone by pressing button
Console will display first transmission received
Press the same button again
Console will display “Confirmed”
Repeat procedure for each of the 4 buttons on the remote
Leave program mode
Proceed to program a user code
- mastercode + 8 + unused user (002-128) + new user code
Select authorisation level required
Open and close reporting (yes/no)
RF button (1 = yes)
Allocate the first of the 4 zone numbers used for the remote when prompted
Loop 4 must be programmed into the system to avoid “check” conditions
* See user programming instructions on page 34 for details
AVAILABLE ZONE TYPES:
Type 06 = 24 Hour Silent Alarm
Type 07 = 24 Hour Aud. Alarm
Type 08 = 24 Hour Aux. Alarm
Type 09 = Supervised Fire
Type 20 = Arm - Stay
Type 21 = Arm Away
Type 22 = Disarming
Type 23 = No alarm response