3.7 Menu Mode Programming
Training Module
MENU MODE PROGRAMMING
• Zone Programming
• Sequential Learning
• Report Code Programming
• Alpha Programming
• Device Programming
• Relay Programming
• Relay Voice Descriptors
• Custom Index
• Answer Yes or No to questions
1 = Yes 0 = No
• System Wide & Partition Specific Fields should be completed first
DEVICE PROGRAMMING - CONSOLES
DEVICES (Keypads, 4204, etc.)
Device Type Home Sounder Supervised Device Type Home Sounder Supervised
Address Partition Option CF? Address Partition Option CF?
00 16
01 17
02 18
03 19
04 20
05 21
06 22
07 23
08 24
09 25
10 26
11 27
12 28
13 29
14 30
15
Type:
0 = device not used
1 = alpha keypad (address 00-30)
3 = RF receiver (address 01-07)
4 = Output Relay module (address 00-15)
5 = Voice Module (address 04 factory set)
Keypad Sounder Options:
00 = no suppression
01 = suppress arm/disarm and entry/exit beeps
02 = suppress chime mode beeps only
03 = suppress arm/disarm, entry/exit and chime mode beeps
A device is anything connected to the Console connections
• Enter Programming
• Press #93
• Enter “0” (4 times) until Device Programming appears, Then enter “1” for Yes
• Device Address Number 01 is already defaulted to an Alpha Console.