Vista 120 Training Guide 49
6.8 4204 Relay Programming
Training Module
Set 4204’ DIP switch for an unused device address 01-15.
Connect 4204 via the flying lead supplied to terminals 6 (RED), 7 (BLACK), 8 (GREEN)
and 9 (YELLOW) of the Vista50P.
Use 6139 console to enter programming mode: installer code + 8 0 0 0
Press # 9 3 to enter Menu Mode.
Press 0 (NO) until “Device Prog?” is displayed, then press 1 (YES).
Enter the two digit Address Number (01 15), as set on the 4204’s Dip Switches
Press * to move to Device Type
Enter a Device Type “4” for Output Device
Press * to move to Supervised CF
Press * to move to Device Address
If more than one 4204 is to be used, follow the same procedure until all output devices
have been programmed, enter 0 0 * to exit “DEVICE PROG?”
Enter * until console displays “RELAY PROG?”, then press 1 (Yes)
The console will display “ENTER RELAY No.”, enter the relay number 1-4. This is a
reference number only, used for identification purposes. The actual module address and
relay number on the module is programmed in the last two prompts. Press * to continue.
The console will display a summary START screen.
Press * and the console will display a summary STOP screen.
Press * to move to “RELAY ACTION” then enter 0 = not used, 1 = close for 2 secs, 2 =
stay closed to 3 = pulse on/off.
Press * to move to “START EVENT” then enter 0 = not used, 1 = alarm, 2 = fault, 3 =
trouble or 4 = restore.
Press * to move to “START ZN LIST” then enter the zone list number (1 to 8) or 0 is a
zone list is not being used.
Press * to move to “START ZN TYP” then, if a zone type/system operation is being used,
enter the appropriate 2-digit code as listed below.
Choices for Start/Stop Zone
Types
Choices for Start/Stop System
Operation
00 = No Response (Not used) 20 = Arming Stay 41 = **AC Power Fail
01 = Entry/Exit # 1 21 = Arming Away 42 = **System Battery Low
02 = Entry/Exit # 2 22 = Disarming (Code+Off) 43 = Communication Failure
03 = Perimeter 31 = End of Exit Time 44 = RF Low Battery
04 = Interior Follower 32 = Start of Entry Time 45 = Polling Loop Failure
05 = Trouble Day/Alarm Night 34 = Code + # + 71 Key Entry 51 = RF Receiver Failure
06 = 24Hr Silent 35 = Code + # + 72 Key Entry 52 = Kissoff
07 = 24Hr Audible 36 = **At Bell Timeout ** 54 = Fire Zone Reset
08 = 24Hr Aux 37 = 2 Times Bell Timeout 55 = Disarm + 1
09 = Fire Alarm or Trouble 38 = Chime 56 = XX Minutes (enter XX in field 1*74 Stop
condition Only)
10 = Interior w/Delay 39 = Fire Alarm 57 = YY Seconds (enter YY in field 1*75 Stop
condition Only)
23 = No Alarm response
(for output relay activation,
such as for access control)
40 = Bypassing 58 = Duress
*** Or at Disarming, whichever occurs earlier)