Vista 120 Training Guide 44
6.4 5804 Bi Directional Wireless Remote
Training Module
Install & program 5882 Wireless receiver(s) as per 5882 Instructions
Ensure that a House ID has been assigned to the Wireless receiver(s)
Terminate the 5800TM on the console bus. The 5800TM should be a minimum distance
of 3 metres away from the panel to stop any interference.
The 5800TM must be programmed as an unused address within the range of 28 through
to 30. Cut the red jumper for an address of 28, white jumper for 29 and both for 30.
Enter program mode.
Device Programming:
Go to location #93 and select Device programming.
Select the address of the 5800TM (28-30) and enable it as an “Alpha Console”.
Exit “Device Programming” (00 = Quit).
Zone Programming:
“Enter Zone programming”
Select an unused zone from 010-128
Program zone type as required (eg. 20= arm stay, 21= arm away, 22= disarm)
Select partition and report code for remote key
Select input type 5 (Button RF)
Learn loop button being used on that particular zone by pressing button
Console will display first transmission received
Press the same button again
Console will display “Confirmed”
Repeat procedure for each of the 4 buttons on the remote
To avoid “check” conditions, Loop C must learnt into the system.
Leave program mode
User Code Programming:
Proceed to program a user code
- mastercode + 8 + unused user (002-128) + new user code
Select authorisation level required
Open and close reporting (yes/no)
RF button (1 = yes)
Allocate the first of the 4 zone numbers used for the remote when prompted
Loop 4 must be programmed into the system to avoid “check” conditions
* See user programming instructions on page 34 for details.