Vista 120 Training Guide
15
3.2 Recommended Programming Procedure
The purpose of this document is to provide a quick and easy way to program your VISTA-120 system. A
recommended programming procedure is included, followed by a list of program fields with the corresponding
program group they belong to (Systemwide, partition-specific, scheduling, etc.).
Following the program forms are system layout worksheets. We recommend that you use these sheets to plan
your system before programming is performed. If you need further information about specific programming
options, see the VISTA-120 INSTALLATION INSTRUCTIONS.
Single Partition System
The system default is for a single partition system. If you are setting up a single -partition system, the
partition-specific fields become Systemwide fields. Follow the steps outlined on page 3 of this
document for proper programming procedure.
Multiple -Partition System
If you are setting up a multi-partition system, you must enter the number of partitions you are using in
data field 2*00. Follow the steps outlined on page 3 of this document for proper programming
procedure.
Make sure that one keypad is connected to the control and is set to device address "00."
RECOMMENDED PROGRAMMING PROCEDURE
The following is a step-by-step procedure recommended for programming your VISTA-120 system.
1. Set the keypads (and other peripheral devices) to the appropriate addresses.
2. Set factory defaults by pressing *97.
This will automatically enable keypad addresses 00-03, so be sure at least one keypad
is set to one of these addresses.
3. Program Systemwide (global) data fields.
Using the programming form as a guide, enter program mode and program all
systemwide programming fields. These options affect the entire system, regardless
of partitions. They include control options, downloader and dialler options, RF
options, event logging options, etc.
Note that field 2*00 (number of partitions) & field 1*32 (RF expander type)
must be programmed before continuing.
4. Program partition-specific fields.
Partition-specific fields can have different values for each partition. When the
systemwide fields have been programmed, program all partition-specific
programming fields by first pressing *91 to select a partition (while still in data field
program mode). Then enter the first partition-specific field number *09. The next
partition-specific field will automatically be displayed when you are finished entering
the value for field *09. To program the fields for the next partition, press *91, enter
the desired partition number, then enter field *09.
5. Use #93 Menu Mode for device programming.
Refer to the DEVICE PROGRAMMING section of the Installation Instructions to
assign keypad ID numbers and default partitions for each keypad, and to selectively
suppress certain keypad sounding options. Also use this mode to assign RF
receivers, relay modules, and the VIP module.