VISTA 120 PROGRAMMING FORM
Some fields are programmed for each partition (shown as shaded fields). See the PARTITION-SPECIFIC section for programming these
fields. Standard default (*97) values are shown in brackets [ ], otherwise default = 0.
1*73 PRINTER BAUD RATE [0]
1=300; 0=1200
1*74 RELAY TIMEOUT XXX MINUTES | | [000]
Enter the relay timeout, 0-127 in multiples of 2 minutes, desired for #80 Menu
Mode time driven event relay command numbers "04/09" and #93 Menu Mode
Relay Programming output command "56".
1*75 RELAY TIMEOUT YYY SECONDS | | [000]
Enter the relay timeout, 0-127 seconds, desired for #80 Menu
Mode time driven event relay command numbers "05/10" and #93 Menu Mode Relay Programming command "57".
1*76 ACCESS CONTROL RELAY Partition-Specific
FOR PART.
1*77 LOG FIRST MAINTENANCE SIGNAL [0] 1= log first maintenance signal; 0= no logging
3rd Page Programming Fields (press *94)
2*00 NUMBER OF PARTITIONS [1] Enter the number of partitions used in this system, 1-8.
2*01 SUMMER TIME | | [04, 10]
START/END MONTH Start End
00-12; if no Summer time, enter 00,00
2*02 SUMMER TIME | [1, 5]
START/END WEEKEND # Start | End
Enter 1-7. 1=first; 2=second; 3=third; 4=fourth; 5=last; 6=next to last; 7=3rd
from last [1,5; 1st Sunday in April, last in Oct.]
2*05 AUTO-ARM DELAY Partition-Specific
2*06 AUTO-ARM WARNING PERIOD Partition-Specific
2*07 AUTO-DISARM DELAY Partition-Specific
2*08 ENABLE FORCE ARM Partition-Specific
FOR AUTO-ARM
2*09 OPEN/CLOSE REPORTS Partition-Specific
BY EXCEPTION Partition-Specific
2*10 ALLOW DISARMING ONLY DURING Partition-Specific
ARMING/DISARMING WINDOWS
2*11 ALLOW DISARM OUTSIDE WINDOW [0]
IF ALARM OCCURS Used only if field 2*10 (partition-specific field) is set to "1". If this field is
enabled ("1") the system can be disarmed outside the disarm window if an
alarm has occurred. If "0", disarming can only be done during the disarm
window. If field 2*10 is set to "0" for a partition, this field has no effect for
that partition.
2*18 ENABLE GOTO FOR THIS PART. Partition-Specific
2*19 USE PARTITION DESCRIPTORS [1] 1=enable 0=disable
2*20 ENABLE J7 TRIGGERS BY PART. Partition-Specific
2*21 ENABLE SUPERVISION PULSES | | [000]
FOR LRR TRIGGER OUTPUTS F B S
Used for supervised connection to a transmitter.
Enter 0 to disable or 1 to enable the listed outputs.
F= Fire; B= Burglary; S= Silent panic/duress.
2*22 DISPLAY FIRE ALARMS OF Partition-Specific
OTHER PARTITIONS
2*23 DISPLAY BURG & PANIC Partition-Specific
ALARMS OF OTHER PARTITIONS
2*24 DISPLAY TROUBLES OF OTHER PARTITIONS Partition-Specific