Vista 120 Training Guide
29
NOTE: The following fields should be preset before beginning: 2*00 Number of Partitions; 1*32 receiver
type. In addition, receivers should be programmed via Device programming.
After programming all system related programming fields in the usual way, press #93 while still in programming
mode to displa
y the first choice of the menu driven programming functions. Press 0 (NO) or 1 (YES) in response
to the displayed menu selection. Pressing 0 will display the next choice in sequence. Menu selections are as
follows:
ZONE PROG?
0=No 1=Yes
For programming the following:
• Zone Number
• Zone Response Type
• Wired zone
• RF Zone
• Right/left Loop Zone
• Serial number RPM zone
• Partition Number for Zone
• Dialler report code for zone
SEQUENTIAL LEARN?
0=no 1=yes
For entering (enrolling) 5800 transmitter & serial number polling loop device serial numbers into
the system.
REPORT CODE PROG
0 = no; 1 = yes
For entering report codes for zones and all system conditions.
ALPHA PROG?
0=no 1=yes
For entering alpha descriptors for the following:
• Zone Descriptors
• Installer's Message
• Custom Words
• Partition Descriptors
• Relay Descriptors
DEVICE PROG?
0=no 1=yes
For defining the following device characteristics for addressable devices, including keypads, RF
receivers (4281/5881/5882), 4285 voice module and 4204 output relay modules:
• Device Address
• Device Type
• Device's Home Partition
• Keypad Options
• Voice Module
RELAY PROG?
0=no 1=yes
For defining output relay functions.
3.5 Programming with #93 Menu Mode