Vista 120 Training Guide 32
DEVICE PROGRAMMING – Cont.
• Enter Device Address Number (01 – 30).
• Press * to move to Device Type
• Enter the Required Device (To Program a 6139 Console – Enter “1”)
DEVICE TYPE DEVICE ALLOWABLE ADDRESS NUMBERS
1 Alpha Console 01 - 30
1 5800TM 28 - 30
3 RF Receiver 01 - 07
4 Output Relay Module 01 – 15
5 VIP Voice Module 04
• Press * to move to Console Partition
Enter the Console’s Home Partition (1-9), Entering a 9 will enable the Console as a Master Console
• Press * to move to Sound Option
• Enter Console Sounder Option Enter the Device Type “1” for Alpha Console
SOUND OPTION SOUNDS SUPPRESSED
0 No Suppression
1 Suppress Arm/Disarm & Entry/Exit beeps
2 Suppress Chime mode beeps only
3 Suppress Arm/Disarm, Entry/Exit & Chime beeps
• Press * to move to Keypad Global
• If Required enter “1” to enable this particular Console to allow Global Arm/Disarm functions.
• If a console is not enabled then a User with Global Arm/Disarming enabled will have to log to each
partition in turn .
• Press * to move to Device Address & Program next Device
• Continue until all Consoles are programmed in
• When finished Enter “00” & “*” to exit Device Address programming