VISTA 120 PROGRAMMING FORM
Some fields are programmed for each partition (shown as shaded fields). See the PARTITION-SPECIFIC section for programming these
fields. Standard default (*97) values are shown in brackets [ ], otherwise default = 0.
1*47 CHIME ON BELL/SIREN Partition-Specific
1*48 WIRELESS KEYPAD ASSIGNMENT [0]
0=disable; enter partition in which RF keypad used, 1-8.
1*49 SUPPRESS TX SUPERVISION [1]
SOUND 1=disable; 0=enable
1*50 No. SECONDS ADDED PER DAY [0]
00-30 = number of seconds needed to be added per day for clock
1*51 No. SECONDS REMOVED PER DA Y [0]
00-30 = number of seconds needed to be removed per day for clock
1*52 SEND CANCEL IF ALARM + OFF Partition-Specific
1*53 DOWNLOAD CALLBACK [0]
1=callback not required; 0=callback required
1*54 INTERNAL CLOCK SYNC. [0] 1 = use internal crystal for real-time clock; 0=use AC sync for clock
1*55 INTERNATIONAL DATE FORMAT [1] 1=DDMMYY; 0=MMDDYY
1*56 AC 60Hz/50Hz [1] 1 = 50Hz; 0 = 60Hz (Aust. Requirement 50Hz)
1*57 5800 RF BUTTON GLOBAL ARM [0] 1 = yes; 0 = no
1*58 5800 RF BUTTON FORCE ARM [0]
Enter "1" to enable. If a zone is faulted after pressing button, keypad will beep
once. User should press button again within 4 sec. to force bypass those
zones. Enter "0" to disable.
1*59 SUPRESS STATUS LED OUTPUT [0]
WHEN ZONE 7 KEYSWITCH 1 =yes
ENABLED / RETAIN VOLTAGE 0 = no
TRIGG. OUTPUTS
1*60 ALARM VERIFICATION [0] Enter 1 If alarm verification is being used; Enter 0 if it is not.
1*61 DISPLAY TAMP[e]R [0]
Enter 1 to display "TAMPR" upon tamper conditions;
Enter 0 to display "CHECK" or "TRBL" depending on state of field 1*07
1*62 TAMPER DETECT IN TEST MODE [0]
Enter 1 to terminate Test mode upon tamper condition;
Enter 0 to ignore tamper conditions during Test mode (displays "FAULT")
1*66 SILENCE SOUNDERS DURING AAV [0] 1=AAV in use; 0=No
1*67 VIDEO ALARM VERIFICATION [0] 1=Yes; 0=Audio Alarrm Verification
1*70 EVENT LOG TYPES
Alrm Chck Byps O/C Syst Test Rpt
1=enable; 0=disable
1*71 12/24 HOUR TIME STAMP FORMAT [0] 1=24 hour; 0=12 hour
1*72 EVENT LOG PRINTER ON-LINE [0]
1=enable; 0=disable