6. Use #93 Menu Mode for zone programming.
Refer to the ZONE PROGRAMMING section of the Installation Instructions to
program zone response types, assign right loop zones and wireless zones, assign
zones to partitions, and to program alarm report codes.
7. Use #93 Menu Mode for programming relays.
Refer to the RELAY PROGRAMMING section of the Installation Instructions to
program desired relay operation.
8. Program Communication options.
Refer to the COMMUNICATION PROGRAMMING section of the Installation
Instructions to load communication defaults and to program related fields. Then use
#93 mode to program report codes if necessary.
9. Use #93 Menu Mode for programming alpha descriptors.
Refer to the ALPHA PROGRAMMING section of the Installation Instructions to
enter zone and partition descriptors and a custom installer's message.
10. Use #93 Menu Mode for programming relay voice descriptors and custom word
substitutes.
Refer to the RELAY VOICE DESCRIPTORS section of the Installation Instructions
for further instructions for programming relay descriptors to be annunciated by the
4285 VIP module, as well as the CUSTOM INDEX section for custom word
substitutes.
11. Use #80 Mode for programming schedules.
Refer to the SCHEDULING section of the Installation Instructions to program
open/close schedules, temporary and holiday schedules, limitation of access
schedules, and time driven events.
12. Define user access codes.
Refer to SECURITY ACCESS CODES section of the Installation Instructions to
program authority level, O/C reporting option, partition assignments, and wireless
key assignments for each user.
13. Exit Programming Mode
Exit programming mode by pressing either *98 or *99. A second entry of *99 is
required if the exit is being done from fields 1*00 and above.
To prevent re-access to Programming mode using the Installer's code, use *98. The
only way to re-access Programming mode is by depressing both the [*] and [#] keys
at the same time within 30 seconds of power up.
Exiting by using *99 always allows reentry into Programming mode using the
Installer's code. Either way of exiting will allow access via downloading. Note that if
local programming lockout is set via downloading, programming mode cannot be
entered at the keypad.
SUMMARY OF PROGRAMMING COMMANDS
To enter program mode, enter installer code + [8] + [0] + [0] + [0]
To set standard defaults, press *97
To set communication defaults, press *94 + one of the following:
*82=Ademco Expanded High Speed; *83=Ademco Contact ID
To change to next page of program fields, press *94
To return to previous set of fields, press *99
To erase account & phone number field entries, press [*] + field number + [*]
To assign zone descriptors, press #93 + follow menu prompts
To add custom words, press #93 + follow menu prompts
To enter Installer's Message, press #93 + follow menu prompts
To exit program mode, press *99 OR *98: *99 allows re -access to programming mode by installer code.
*98 prevents re-access to programming mode by installer code.