Vista 120 Training Guide 42
5882 Wireless Expansion cont….
Training Module
ADDITIONAL WIRELESS PROGRAMMING
1*28 “RF TX Low Battery Sound”. Enter 1 for immediate, or 0 for when disarmed
1*29 “RF TX Low Battery Report Enable”, enter 1 (Yes) or 0 (No) for dialler report.
1*30 “RF Receiver Check-In Interval”, Default 0 6 (Sets 12 hour interval).
1*31 “RF Transmitter Check-In Interval”, Default 1 2 (Sets 24 hour interval).
1*44 “Wireless Keypad Tamper Detect”, enter 1 to enable or 0 to disable.
1*48 “Wireless Keypad Assignment”, enter 1-8 for the partition where the keypad will be
used.
1*49 “Suppress TX Supervision Sounding”, enter 0 to enable audible trouble sounds for
transmitter for check-in failure.
1*57 “5800 RF Button Global Arm”, enter 1 to have the system Arm/Disarm following the
button user’s global arm settings or enter 0 if not.
1*58 “5800 RF B utton Force Arm”, enter 1 to enable the RF button user to force bypass all
faulted zones. When attempting to arm the system, the console will beep once after pressing
the button if any faulted zones are present. If this feature is enabled, the user should then
press the button again within 4 seconds to force bypass those zones and arm the system.
Enter 0 to disable.
For more information see pages 30 to 39 of the Vista 120a Installation and Programming
Guide and the Installation Instructions accompanying the 5882 Receiver.