Vista 120 Training Guide 35
4. Communications
Training Module
COMMUNICATION DEFAULTS (Program after all Zones are programmed)
• This enables all Zones to report
• This Enables all “Zone Types” to send Restores
• This does not Enable Zones Restores, Supervisory or System Reporting
To Load Contact ID communication defaults
• Whilst at 1
st
Level of Programming
• Press *94 to move to the second level
• Press * 83 to Load Defaults
• Enter “1” to Default to Contact ID (see Defaults on p.134 – 138 of V120a Installation & Setup Guide)
REPORT CODE PROGRAMMING
• Whilst at 1
st
Level of Programming Press #93 & enter Menu Mode
• Press #93
• Select Report Code Programming
• Press * to move to Alarm, ID Digit
• Answer No “0” to Alarm, ID Digit (These were enabled when the Contact ID Defaults were Loaded)
• Answer Yes “1” to Restore, Supv Codes
• Enter one Zone from Each Group of 16 Zones (001-016, 017-032, etc)
• Press * to continue
• Enter a “01” followed by a “*” to enable each report required (See above Table) or just press “*” to leave
disabled
• Repeat as required for each Group of 16 Zones by entering one Zone from the next group of 16 zones
• When finished programming “Restore / Supervisory Codes”, Enter “000” at the Zone number prompt.
• To Move to System Group #1 enter a “0” (No) when asked if you wish to Quit Report Menu
• Then Answer “1” Yes or “0” No to Program System Group #1
• To Enable these reports enter 1st digit as “01”
• 2
nd
digit can be left as “00”
• When you have finished programming these report codes the system will prompt: Quit report Menu?
• To Enter System Group #2 Press “1” (Yes)
• Program as per System Group #1
4.1 Setting the Clock
• Enter Installer Code #63
• Enter value required and press * to move along
• See Page 142 – Installation Instructions
Comentarios a estos manuales