VISTA-15/VISTA-15CN Installation and Setup Guide
17–2
2. Zone List (ZL) is a group of zones to which the
Event
applies in order to
activate a particular device. Note that there are 3 output device-related
zone lists that can be programmed in
81 Menu mode; when the selected
Event (alarm, fault, or trouble) occurs in any zone in the selected
START
zone list (1, 2, or 3), activation of the selected device will
START
.
Start by Zone Type or System Operation
1. If a System Operation, such as
disarming
or
any
fire alarm,
is to
activate the device, the appropriate choice would also be entered under
the
Zone Type
option.
Zone Type
is used independently of the
“EVENT/ZONE LIST” combination.
If a
Zone Type
is chosen, any zone of that response type going into
alarm, trouble, or fault causes the device to activate as selected in
“ACTION.” If the same
Zone Type
is also chosen for the STOP
programming, any zone of that type that restores also deactivates the
device.
If a
System Operation
is chosen (for example, end of exit time), that
operation causes the device to activate as selected in ACTION. The
different choices for
Zone Type
and
System Operation
are listed in
“Programming Output Relays and Powerline Carrier Devices” later in
this section, and in the Programming Form.
STOP (STP):
The
STOP
programming determines when and under what conditions the
device is deactivated. The following options are available:
Upon Restore of a Zone List
1. Restore Zone List (ZL): If a
Zone List
is used as the STOP event, the
device deactivates when all the zones in that list restore from a previous
fault, trouble, or alarm condition. This occurs regardless of what is
programmed to
START
the device; therefore, a "RESTORE ZONE LIST"
would normally only be used when a
Zone List
is used to
START
the
device.
Upon a Zone Type or System Operation
1. Zone Type/System Operation: Instead of using a "RESTORE ZONE
LIST," a specific zone (response) type or system operation action can be
selected to deactivate the device.
If a specific
Zone Type
is chosen, any zone of that response type that
restores from a previous alarm, trouble, or fault condition causes the
device to deactivate.
If a
System Operation
is chosen, that operation causes the device to
deactivate. The different choices for
Zone Type
and
System Operation
are listed in “Programming Output Relays and Powerline Carrier
Devices” later in this section, and in the Programming Form.
During normal system operation, you may START any device manually by a keypad entry of:
Code + # + 7 + n; or STOP it manually by a keypad entry of: Code + # + 8 + n, where n = the
device number to be controlled.
As a
minimum
, the ACTION
(
A
)
field must be pro
g
rammed for this manual action to be operative.