Section 14 - Zone Response Type Definitions
14–3
Type 10
Interior w/Delay
This zone type gives
Entry Delay
(using the programmed entry
time), if tripped when the panel is armed in the AWAY mode. Entry
Delay begins whenever sensors in this zone are violated, regardless
of whether or not an Entry/Exit Delay zone was tripped first. No
Entry Delay is provided if tripped when the panel is armed in the
MAXIMUM mode. Exit Delay is present for any arming mode. This
zone type is bypassed when the panel is armed in the STAY
or INSTANT mode. If the panel is armed NIGHT-STAY, this
zone type is not bypassed if it is on the NIGHT-STAY Zone List
05.
Type 12
24 Hour Monitor
This zone type is a dynamic monitor of a zone fault/trouble. In the
case of a short/open, the message, "*ALARM*-24 Hr. Non-Burg. -
#XXX " (where XXX is the zone number) is sent to the Central
Station. The system keypad displays a fault message indicating the
appropriate zone. Upon restoral of the zone, the message,
"*RESTORE*-24 Hr. Non-Burg. -#XXX " is sent to the Central
Station. The fault message automatically disappears from the
keypad. The zone restores dynamically; therefore, a User Code +
OFF sequence is not needed to reset the zone. Faults of this zone
type are independent of the system, and can exist at the time of
arming without interference.
If you want to use this zone type to activate a relay, all zones of
Type 12 must be placed into a zone list and triggered by a “fault”
event. The same zone list must be programmed for the “STOP”
event. A restore of every faulted zone in that zone list is required to
deactivate the
relay
.
Type 20
Arm-STAY
This is a special-purpose zone type, used with 5800 Series Wireless
Pushbutton units, which results in arming the system in the STAY
mode when the zone is activated. Pushbutton units send the zone
number as a user number to the Central Station when arming or
disarming.
Type 21
Arm-AWAY
This is a special-purpose zone type, used with 5800 Series Wireless
Pushbutton units, which results in arming the system in the AWAY
mode when the zone is activated. Pushbutton units send the zone
number as a user number to the Central Station when arming or
disarming.
Type 22
Disarm
This is a special-purpose zone type, used with 5800 Series Wireless
Pushbutton units, which results in disarming the system when the
zone is activated.
Type 23
No Alarm Response
This zone type can be used on a zone when an output relay action is
desired, but with no accompanying alarm (e.g., lobby door access).
Type 24
Silent Burglary
This zone type provides an instant alarm, with no audible
indication at any keypad or external sounder, if the zone is faulted
when the system is armed in the AWAY, STAY, NIGHT-STAY,
INSTANT, or MAXIMUM mode. This zone type is usually assigned
to all sensors or contacts on exterior doors and windows where bells
and/or sirens are NOT desired. A report is sent to the Central
Station.
All of the zone types described are available for the wireless portion of the system, if used.
The reaction of a zone type is changed if the zone itself is included in either Zone List 04 or Zone
List 05. See
Section 18. Zone Lists
for further explanation.