Vista de pagina 112
24–1
SECTION 24
Troubleshooting Guide
••••••••••••••••••••••••••••••••••••••••••••••••••
SYSTEM (including Wireless)
SYMPTOM POSSIBLE CAUSE REMEDY
1. Transmitter signal not
received at
5881/5882.
1a. Transmitter or 5881/5882 not properly
powered.
1a Check or change transmitter's battery.
Check VISTA-15/VISTA-15CN's AC
power.
1b. If transmitter
is
5827/5827BD
: House
Code not set in field
24, or transmitter
not set to same House Code set in that
field.
1b. Check code switches inside transmitter.
Must match with RF House Code
programmed in VISTA-15/VISTA-
15CN.
1c. Transmitter located too far from RF
receiver.
1c. Move transmitter or RF receiver.
1d. Metal shielding between transmitter and
RF receiver.
1d. Check for large metal obstructions,
then relocate transmitter if necessary.
1e. Transmitter malfunctioning. 1e. Verify by activating 5881/5882 with
another, similar transmitter. If OK
now, return defective transmitter.
1f. 5881/5882 malfunctioning. 1f. Verify by making sure other
transmitters cannot activate 5881/5882.
If defective, replace and return original
5881/5882.
1g. Transmitter no. (zone) not programmed. 1g. Verify programming.
1h. 5881/5882 address incorrect. 1h. Set DIP switch on 5881/5882 for
address “0.
1i. Field
22 not set properly. 1i. Set field
22 for “1.”
2. Transmitter zone number
appears during Transmitter
Sniffer mode, but does not
clear.
2a. Transmitter zone type (ZT) is set to
00
(Not Used).
2b. Transmitter battery not installed.
2a. Set ZT to a valid active zone type in
field
56 or
58.
2b. Install proper battery.
2c. 5800 system transmitter not
enrolled
in
system.
2c. Enroll unit in field
56 or
58.
3. LOW BATTERY message on
keypad
3a.
Bat
or
System Lo Ba
t (no zone nos.):
System battery is low or missing.
3b.
Bat
or
Lo Bat
+
00
: Remote RF keypad
battery is low.
3a. Verify that battery charging circuit is
working. If OK, replace battery.
3b. Replace remote RF keypad battery.
3c.
Bat
or
Lo Bat
+
nn
: Transmitter for zone
“nn” has a low battery.
3c. Replace transmitter battery in zone
"nn."
4. Periodic beep(s) from
keypad.
4a. System is in Test mode.
4b. A transmitter low battery has occurred
and is displayed.
4c. A supervision Check has occurred.
4a. Enter [Code] + [1] OFF to exit Test
mode.
4b. Enter [Code] + [1] OFF and replace the
battery.
4c. Check the transmitter indicated.
Restore communication to the receiver
to cancel the condition.
5. With 5800 system, no
response to a transmitter in
normal operation, although
zone number clears during
Transmitter Sniffer mode.
5a. Put control in Test mode. If zone does not
respond, try operating the tamper switch
or another input to the transmitter.
If another input causes the zone to be
displayed, the wrong input was
enrolled
when programming.
5a. Delete input's serial number (not the
zone), and enroll the proper input (see
field
56 or
58
).
5b. If no response at all from this transmitter,
this physical transmitter has not been
enrolled by the system. Transmitter
Sniffer display is being cleared by another
unit programmed for this zone.
5b. Determine which transmitter is
programmed for this zone and
reprogram as necessary.
Vista de pagina 112