VISTA-15/VISTA-15CN Installation and Setup Guide
4–4
Programming Hardwired Zones
Each zone must be programmed into the system using the
56 Zone Programming Mode or
58 Expert Programming Mode, which assigns characteristics that define the way the system
responds to faults on that zone. Refer to Section 14: Zone Response Type Definitions and
Section 16: Zone Programming for specific instructions on programming hardwired zones.
Checkout Procedure for Hardwired Zones
After complete installation and programming of all hardwired devices, check the security
system as follows:
1.
Make certain that all devices and sensors connected to the hardwired zones are not in a
faulted state. Doors and windows with contacts should be closed, PIRs should be covered
(use a cloth to mask them temporarily, if necessary).
2.
Plug in the AC transformer if you have not already done so.
With all hardwired zones intact, the alpha keypad connected to the system should display:
✱✱✱✱
DISARMED
✱✱✱✱
READY TO ARM.
3.
If the following is displayed,
DISARMED
Press
to show faults
press [
]
to display the faulted zone(s). Restore any faulted zone(s) as necessary (also
make sure that you have connected a 2000 ohm
EOL resistor
across the terminals of
unused zones).
When the
DISARMED...READY TO ARM
message is displayed, you can proceed to the
next step.
4.
Fault and then restore every contact or sensor on each zone individually to ensure that it
is being monitored by the system. Each time a zone is faulted, the keypad should display
the number of the faulted zone. When each zone is restored, the
READY TO ARM
message should appear again.
You need to observe the keypad as each zone is faulted and restored.
When you get the proper displays on the keypad(s), the hardwired zones in the system are
functioning properly.
5.
Unplug the AC transformer.