ADEMCO Accord Especificaciones

Busca en linea o descarga Especificaciones para Los Sistemas De Control De Acceso De Seguridad ADEMCO Accord. ADEMCO Accord Specifications [en] Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - INSTALLATION INSTRUCTIONS

iINSTALLATION INSTRUCTIONSII1-1200 Issue B

Pagina 2

4 25For example, to programme User Code 2 as 2626: Enter the Master User Code. Press: 8 2 2626. Two beeps confirm that the new code has been acce

Pagina 3 - Table of Contents

5SECTION 2: INSTALLINGTHE ACCORDFixing the EnclosureThe two parts (lid and base) of the Accord control panel enclosure are connected by: Five pilla

Pagina 4

6Figure 2.2 Enclosure Base Layout.Spares PackThe Accord control panel comes with a spares pack. This contains ten zone links, fivemounting pillars and

Pagina 5 - CONNECTIONS

7Assembling the Control Panel Into theEnclosure1. Insert the four plastic PCB support pillars into the four holes in the enclosurebase, see Figure 2.2

Pagina 6 - SPECIFICATIONS

8Connections to the AccordMounting and Wiring the LED Remote KeypadTo mount and wire the Accord LED keypad:1. Press down the two base clips recessedon

Pagina 7 - SAFETY INFORMATION

9Connecting the External SoundersConnections for Self Actuating Bells and Bell/Siren combinations should be made asoutlined in Table 2.2 Connections f

Pagina 8 - WHAT THEY MEAN

10Figure 2.4 Connections to the Accord.Testing the InstallationPower-up and Initial Test ProcedureWhen the Accord control panel has been installed in

Pagina 9

111. Apply input power to the mains transformer.2. Check that the Auxiliary Voltage at terminals AUX + and AUX  on the mainterminal strip measures be

Pagina 10

12SECTION 3: PROGRAMMINGTHE ACCORDGetting In and Out of Programming ModeAll zone and system programming must be carried out from Programming Mode. To

Pagina 11 - THE ACCORD

13Programming Groups 1, 2 and 3Programming Groups one to three are used to programme the eight zones for each ofthe three setting modes: Full, Part an

Pagina 13 - SECTION 4: OPERATING

14Zone Programming  Group 3 Night Set The first digit entered is 3 for Night Set. The second digit is the zone number (1  8). The third digit is

Pagina 14 - Connections to the Accord

iiiTable of ContentsSECTION 1: WIRING AND SAFETY INFORMATION ... 1Wiring and Safety Information ...

Pagina 15 - Zone Type Definitions

ivSystem Programming  Group 4 System Options ... 14Group 4  Option 1 Exit Time ...

Pagina 16 - Defaults

vDisabling the Chime Function On All Zones ... 25Viewing the Log [0] ...

Pagina 17 - Wiring the Zones

vi 29APPENDIX A:SPECIFICATIONSPanel SpecificationPhysical Width: 195 mmHeight: 285 mmDepth: 90 mmElectrical Mains Input: 230 V a.c. (+10% -8%) 50 Hz

Pagina 18 - SECTION 3: PROGRAMMING

1SECTION 1: WIRING ANDSAFETY INFORMATIONWiring and Safety InformationIt is essential that this product is installed correctly, in particular with resp

Pagina 19 - Programming Groups 1, 2 and 3

2Knockouts must only be removed if cables are to enter the cabinet at that point. Thehole must be covered by the trunking or conduit or by means of a

Pagina 20 - Programming System Options

3FusesThe mains fuse within the cabinet is rated at 100 mA.The mains supply must be disconnected before opening the cabinet and changingthe fuse. Repl