3
Fuses
The mains fuse within the cabinet is rated at 100 mA.
The mains supply must be disconnected before opening the cabinet and changing
the fuse. Replace the mains fuse with the same type and rating, that is:
Rating: 100 mA anti-surge (T).
Construction: Glass cartridge.
Dimensions: 20 mm length, 5 mm diameter.
Conformance: BS EN 60127-2 and IEC127-2.
There are three on board fuses:
F1 Battery: 1A 20mm, Anti-surge.
F2 Keypad/Aux power: 500 mA 20mm, Anti-surge.
F3 Bell: 500 mA 20mm, Anti-surge.
Equipment Electrical Rating
The control equipment is designed to operate on a UK mains supply of 240 Volts a.c.
(230 V +10% 8%) at a frequency of 50 Hz. It is not suitable for other types of supply.
The maximum current consumption in normal use is 80 mA.
Batteries
The battery used with the control panel must be a 12 V sealed lead-acid rechargeable
battery of up to 7.2 Amp-hour capacity. The battery must be positioned on the battery
shelf. The battery leads must be connected to the battery observing terminal polarity
and not left hanging near the mains terminal block .
26
Viewing the Log [0]
To view the 16-event zone activation Log:
Enter your User Code and press 0.
The LED corresponding to the zone most recently activated lights and the
keypad beeps once.
The system works its way through the history of the zone activations.
If a zone has been activated two or more times in succession the zone LED will
remain lit and a beep will be heard for each activation.
Keypad panic conditions are indicated by all Zone LEDs lighting together.
The keypad beeps twice in rapid succession at the end of the Log display.