7
Assembling the Control Panel Into the
Enclosure
1. Insert the four plastic PCB support pillars into the four holes in the enclosure
base, see Figure 2.2.
2. Place the main PCB on top of the pillars so that the tops of the pillars locate
into the PCB mounting holes.
3. Carefully apply pressure to the PCB in the area immediately surrounding each
of the PCB mounting holes using two thumbs so that the PCB rests firmly onto
the shoulders of the pillars.
Note: Excessive pressure on the PCB will cause irreparable damage.
SW1 Accord Tamper
Switch SW1 on the Accord control panel PCB is the control tamper. Removing the
enclosure lid releases the tamper switch; this causes a tamper alarm if the system is
not in Programming Mode.
RV1 Loudspeaker Volume
The variable resistor RV1, see Figure 2.1, alters the volume of the loudspeaker output
from the control panel.
Note: This affects the volume of the exit/entry tones from the output but not the
Alarm tones.
Zone Links
The eight zones, the zone tamper and the bell tamper circuits can be shorted using the
Zone Links provided in the spares pack. It is strongly recommended that this is done
if any the these circuits are not to be used.
22
SECTION 4: OPERATING
THE ACCORD
Setting and Unsetting the system
Before setting the system:
Ensure all doors and windows are secure.
Ensure that none of the movement detectors are obstructed.
Full Set [1]
To Full Set the system:
Enter your User Code then press the 1 (Full Set) key.
A constant exit tone is heard which changes to a broken tone as you pass the
detectors (except Final Exit zones) on the exit route.
The Day LED will flash during the Exit Time.
To cancel the setting procedure press the Ö (Escape) key.
Once the system sets two confirmation beeps are emitted by the keypad and
internal speaker; after this the Ö (Escape) key does not function.
Easy Set allows users to Set the system without entering their User Code. If Easy Set
is programmed you may set the system by pressing the # key, then the 1 (Full Set) key.
See SECTION 3: Programming the Accord; Group 4 Option 8 Easy Set.
Part Set [2]
To Part Set the system:
Enter your User Code then press the 2 (Part Set) key.
This starts the setting of the system using the Part Set zone programming.
This allows a sub-set of the system to be set.
The Day LED will flash during the Exit Time.
To cancel the setting procedure press the Ö (Escape) key.
Once the system sets two confirmation beeps are emitted by the keypad and
internal speaker; after this the Ö (Escape) key does not function.
The activation of the keypad buzzer and internal speaker are dependant on the
programming of Programming Group 4 Option 4 Part Set Exit Warning.
Easy Set allows users to Part Set the system without entering their User Code. If
Easy Set is programmed you may set the system by pressing the # key, then the 2
(Part Set) key. See SECTION 3: Programming the Accord; Group 4 Option 8 Easy
Set
.