Section 15 - Data Field Descriptions
15–5
✱
43 PRIMARY SUBS ACCOUNT NO. 15 | 15 | 15 | 15
See box at left.
✱
44 SECONDARY SUBS ACCOUNT NO. | | |
See box at left.
✱
45 PHONE SYSTEM SELECT 1
If Central Station receiver is not on WATS line:
0 = pulse dial
1 = tone dial
If Central Station receiver is on WATS line:
2 = pulse dial
3 = tone dial
For Fields
•
43 and
•
44:
Enter digits 0–9;
# +11=B; # +12=C;
# +13=D; # +14=E;
or # +15=F.
Enter
[
✱
]
as the fourth
digit if a 3-digit account
number (for 3+1 dialer
reporting format) is used.
Enter 0 as the first digit
of a 4-digit account
number for Nos. 0000-
0999. Exit field by
pressing
✱
(and press
next field number) if only
3 digits are used.
To clear entries from
field, press
✱
43
✱
or
✱
44
✱
.
See separate
Programming Form for
examples of account
number entries.
✱
46 REPORT FORMAT 7
7
0 = 3+1; 4+1 ADEMCO Low Speed Standard
Prim. Sec.
1 = 3+1; 4+1 Radionics Standard
2 = 4+2 ADEMCO Low Speed Standard
3 = 4+2 Radionics Standard
6 = 4+2 ADEMCO Express
7 = ADEMCO Contact ID Reporting
8 = 3+1; 4+1 ADEMCO Low Speed Expanded
9 = 3+1; 4+1 Radionics Expanded
Enter [
✱
]
as the 4th digit of
✱
43 through
✱
46, if 3+1 dialer reporting is to be
used.
For an explanation of these formats, see Section 21: System Communication.
NOTE: The maximum number of Alarm and Alarm Restore reports during
one armed period is determined by field
✱
93.
✱
47 SPLIT/DUAL REPORTING 0
Use options 0 - 5 when reporting to standard telephone receivers:
TO PRIMARY PHONE NO. TO SECONDARY PHONE NO.
0 = All reports None, unless primary fails; then
all
1 = Alarms, Restore, Cancel Others
2 = All except Open/Close, Test Open/Close, Test
3 = Alarms, Restore, Cancel All
4 = All except Open/Close, Test All
5 = All reports All
Use options 6 - 9 when reporting to a pager is desired:
TO PRIMARY PHONE NO. TO PAGING NO. (Secondary)
6 = All reports except Open/Close Alarms, Open/Close, for users 5-
25
‡
, Troubles
7 = All reports Alarms, Troubles
8 = All reports Alarms, Open/Close, for users 5-
25
‡
, Troubles
9 = All reports except Open/Close Open/Close for users 5-25.
‡
‡
Reports users 5-16 and, if using wireless button-type devices, reports the
zone number of the arm or disarm button (10-25). Open/Close for users 1-4
are not reported.