Section 6 - Wireless Expansion
6–3
Installing the 5800TM Module
Installation of this module is necessary only if you are using one or more 5827BD wireless bi-
directional keypads, 5804 or 5804BD transmitters (wireless keys).
Mounting the 5800TM Module
The 5800TM must be located next to the RF receiver (between one and two feet from the
receiver’s antennas). The 5800TM must not be installed within the control cabinet. Mount
the unit using its accompanying mounting bracket.
Wiring the 5800TM Module
Connect the 5800TM to the control panel’s keypad connection terminals, using the supplied
connector with flying leads, as follows:
Wire Terminal on Control
BLACK (Ground) Terminal 4
RED (+12VDC) Terminal 5
GREEN (Data to Control) Terminal 6
YELLOW (Data from Control) Terminal 7
BLUE Not Used
Do not cut any of the jumpers on the 5800TM when using it with the VISTA-15/VISTA-15CN.
For additional information, refer to the 5800TM’s instructions.
Jam Detection and Reporting
When field 22, option 4 (in Data Field Descriptions) is selected, a 5800 series receiver
detecting a jam condition sends an E344 (RF Receiver Jam Detect) Contact ID report to the
Central Station. At the same time, a Rcvr Jam (alpha keypads) or CHECK 90 (fixed-word
keypads) message alternates with the present system message on the keypad. When the jam
condition is cleared, a Restore message is sent to the CS. Entering a code and OFF restores
the keypad display.
The default for this option is 0 (disabled).
Normal use of a 5827 wireless keypad may cause a false RF jam message to be displayed
in systems that have been programmed for RF Jam Detection.
About 5800 Series Transmitters
Programming Wireless Zones
5800 Series transmitters have built-in serial numbers that you must “enroll” into the system
using the
56 or
58 Zone Programming mode, or input to the control via the downloader.
5800 Series transmitters (except 5827, described separately) do not have DIP switches.
Program each transmitter's zone number into the system using
56 or
58 mode (see
Section 16: Zone Programming). Some transmitters, such as the 5816 and 5817, can
support more than one “zone” (referred to as loops or inputs). On the 5816, for example, the
wire connection terminal block is loop 1, the reed contact is loop 2. Each loop must be
assigned a different zone number.
U
L
The 5816 and 5817 transmitters do not have EOL supervision of their loop wiring. Therefore, for
UL Household Burglary installations, the loop wiring may not exceed 3 feet.