15–1
SECTION 15
Data Field Descriptions
••••••••••••••••••••••••••••••••••••••••••••••••••
In This Section
♦
Descriptions of System Data Fields
••••••••••••••••••••••••••••••••••••••••••••••••••
Descriptions of System Data Fields
NOTE: The blank
PROGRAMMING FORM
should be used to record the data for this
installation. Defaults (where applicable) are indicated in boxes.
The following pages list all data fields in the VISTA-15/VISTA-15CN in numerical order. If
you have performed the programming instructions that were included with the installation of
each of the peripheral devices covered in previous sections, this table simply serves as a
reference for all data fields in the system. If you have decided to program all the data fields
in the system at one time (and therefore did not perform the programming indicated
previously in each section), you can use this listing to program all the data fields now.
SYSTEM SETUP
(
✱
20 -
✱
30)
✱
20 INSTALLER CODE
4 | 1 | 1 | 2
The Installer code is used to enter the 4-digit Master security code in the
normal operation mode, via the keypad. See paragraph titled “Master Code”
in
Section 22: System Operation
for procedure.
Enter 4 digits, 0–9.
✱
21 QUICK ARM ENABLE
0
0 = do not allow Quick Arm
1 = allow Quick Arm (the # key can be used instead of the security code
when arming the system)
✱
22 RF SYSTEM
0
0 = no RF receiver used
1 = 5881/5882 RF receiver used
without RF Jam Detection
4 = 5800 with RF Jam Detection
✱
23 FORCED BYPASS FUNCTION
0
0 = no
Forced
Bypass
1 =
provide
automatic bypass of all open (faulted) zones
All
zones
bypassed by this function are displayed after the bypass is
initiated.
UL
installations
: Must be 0 (no forced bypass)
✱
24 RF HOUSE ID CODE
0 | 0
00 = disable all wireless keypad usage
01-31 =
House
ID
The House ID identifies receivers and wireless keypads.
If a 5827 or 5827BD Wireless Keypad or 5804BD Transmitter is to be used, a
House ID code MUST be entered, and the keypad should be set to the same
ID.