Section 22 - System Operation
22–5
NOTE: It is not possible to arm the system as long as one of the above conditions exist
(unless these zone(s) are bypassed). If the system is in the armed mode when the high
resistance condition occurs, this display does not appear, but does appear as soon as the
system is disarmed. Check the sensor or the loop wiring for the displayed zone.
When the problem has been corrected, the display can be cleared by entering the Off
sequence (code plus OFF key)
twice
.
A Trouble report is sent to the Central Station if a single Cross Zone is faulted in the
armed mode after the Cross Zone timer expires. See
60 and
85 in
Section 15: Data
Field Descriptions.
A display of
BAT
(fixed-word keypads) or
SYSTEM LO BAT
(alpha keypads) with
no
zone number indicates that the system's main standby battery is weak.
A display of
BAT
(fixed-word keypads) or
LO BAT
(alpha keypads)
with
a zone number
and
periodic beeping at the keypad indicates that a low-battery condition exists in the
wireless sensor displayed (zone
00
indicates a wireless keypad). If the battery is not
replaced within 30 days, a
CHECK
display may occur.
NOTE:
Some wireless sensors contain a nonreplaceable long-life battery that requires
replacement of the entire unit at the end of battery life (for example, Nos. 5802, 5802CP,
5804).
Telephone Line Failure
A display of
94
(fixed-word keypads) or
TELCO FAULT
(alpha keypads) indicates that a
monitored telephone line (if programmed in field
92) has been cut (or disconnected).
Depending on how the system was programmed, the keypad may also produce a trouble
sound, and the external sounder may be activated. Silence by entering Installer code plus
OFF.
Power Failure Displays
If there is
no
keypad display
at all
and the
POWER
indicator (if present) is not lit,
operating power for the system has been lost and the system is inoperative.
If the message
AC LOSS
(alpha keypads) or
NO AC
(fixed-word keypads) is displayed, and
the
POWER
indicator (if present) is off, the system is operating on battery power only.
If the battery standby capacity is used up during a prolonged AC power outage,
the
control's auxiliary power shuts down to minimize deep discharge of the battery.
Other Displays (fixed-word displays are in parentheses)
Busy-Standby (dI) If this remains displayed for more than 1 minute, the system is
disabled.
Modem Comm (CC) The system is in communication with the Central Station for change of
function or status verification.
Comm. Failure (FC) A
communication failure
has occurred.
Open Circuit (OC) The keypad is not receiving signals from the control and sees an open
circuit.
Long Rng Trbl (bF) Backup
LRR (Long Range Radio) communication failure
.
Bell Failure (CHECK 70) Bell supervision
failure
.
Rcvr Jam (CHECK 90) RF receiver jam detected.