VISTA-15/VISTA-15CN Installation and Setup Guide
24–2
SYSTEM (including Wireless - cont'd)
SYMPTOM
POSSIBLE CAUSE REMEDY
6. Nuisance or phantom
alarm.
6a. Sensors not properly installed, wired, or
monitored.
6a. Check installation to see if in accordance
with established procedure.
6b. Universal transmitter 5817) programmed
wrong.
6b. Check programming switches on
transmitter.
7. Intrusion alarm for no
apparent reason.
7a. Protected door or window opened while
system armed.
7a. Check with all occupants of protected
home.
7b. Improper user operation of exit/entry
delays.
7b. Check setting of entry and exit delays.
7c.
Magnets
located too far from switches,
and/or doors and windows not properly
aligned.
7c. Check all openings for proper switch and
magnet orientation.
8. “CHECK” and zone number
2–6 are displayed.
8a. Control has sensed a high-resistance
condition on a loop in one of the
hardwired zones (2–6).
8b. Control has sensed a short on one of the
hardwired zones (2–6), and the Hardwire
Short Detection field, 30, is enabled.
8a. Check the sensor or the loop wiring in
the affected zone. The system will not
arm until this condition is corrected (or
the affected zone is bypassed).
8b. Check the sensor or the loop wiring in
the affected zone for a short(s). The
system will not arm until this condition
is corrected (or the affected zone is
bypassed).
CONTROL
SYMPTOM POSSIBLE
CAUSE REMEDY
1. AC POWER light off.
1a. Interrupted AC power supply. 1a. Check transformer connection and
powerline circuit breaker.
2. Digital communicator
message not being received.
2a. VISTA-15/VISTA-15CN in Test mode.
2b. Telephone connection not secure.
2c. Digital communicator malfunctioning.
2d. Telephone number in program needs
prefix or access code.
2e. Telephone call to central monitoring
station requires operator assistance.
2a. Remove from Test mode.
2b. Check all connections.
2c. Check with a different VISTA-15/VISTA-
15CN.
2d. Program prefix or access code into the
VISTA-15/VISTA-15CN.
2e. VISTA-15/VISTA-15CN system cannot
work in this situation.
3. Does not arm properly.
3a.
READY
light not on. 3a. Check for faulted zones and make intact,
or use Bypass arming, if desired.
4. VISTA-15/VISTA-15CN
doesn't respond to
keystrokes on keypad.
4a.
CC
or
MODEM COMM
displayed:
System is in communication with
downloader at Central Station.
4b.
dI
or
SYSTEM BUSY
displayed: System
has just been powered and is in its 1-
minute initialization.
4c.
E4
or
E8
displayed: More zones have
been programmed than the zone
expansion modules can handle.
4d. Keypad address setting incorrect.
4a. Wait until download session is finished.
4b. To bypass this time, press [#] + [0].
4c. Delete some zones or use a higher
capability RF receiver.
4d. Keypads must be set for address 31 (non-
addressable mode).
SMOKE DETECTOR
SYMPTOM POSSIBLE
CAUSE REMEDY
1. Detector alarms, no
apparent reason.
1a. Dust, dirt in sensing chamber.
1b. Improper location.
1c. Unit malfunctioning.
1a. Clean unit's sensing chamber with
vacuum cleaner per unit's instructions.
1b. See unit's instructions for locations to
avoid. Relocate as necessary.
1c. Replace detector.
2. Detector's siren sounds.
2a. Unit not receiving required power.
2b. Unit malfunctioning.
2a. Check for proper installation of battery.
Try new battery.
2b. Replace detector.