Section 16 - Zone Programming
16–3
10 INPUT S/N: L
A022-4064 1
Note:
The [A] and [B] keys
may be used to move the
cursor to the right (A) or left
(B) within the serial number
field, thus allowing you to
correct any entry errors that
may have been made.
Serial number Entry and Loop Number Entry.
Used only when enrolling wireless transmitters.
a.
Transmit two open and close sequences. If using a button-type
transmitter, press and release the button twice
OR
b.
Manually enter the 7-digit serial number printed on the label of
the transmitter, using the alpha display keypad.
OR
c.
To copy the serial number previously enrolled (used when
programming a transmitter with several input loops), simply
press key [C].
The cursor then moves to the “L.” You can edit the loop number, if
necessary. When the loop number is acceptable, press [
✱].
10 INPUT S/N L
A022-4064 ?
NOTE:
If you use the [C] key to copy the previously enrolled
serial number, the cursor moves to the Loop column (L) with the
previous serial number displayed, and displays a question ‘?”
mark for the loop number.
Enter the loop number and press [
✱].
The system then checks for a duplicate serial/loop number
combination.
If a duplicate serial/loop number combination is found, the keypad
emits a single long beep, and prompts with a “?” again for a
different loop entry.
10 INPUT S/N L
A022-4064 1
If serial/loop number combination is not a duplicate in the
system, a display showing the serial number and loop number
entry appears.
Press [
✱
] to continue.
To Delete a Serial
Number
→→
To delete an existing serial number, enter 0 in the loop number
field. The serial number changes to 0's.
10 INPUT S/N:
L
A000-0000 0
If 0 was entered in error, simply re-enter the loop number, and
the serial number returns to the display.
Press [
✱] to accept.
XMIT
TO
CONFIRM
PRESS
✱
TO SKIP
Confirmation Option:
This prompt only appears if you answered
Yes at the first prompt in this section on page 16-1.
T
he system enters a confirmation mode so that the operation of the
actual programmed input can be confirmed. Activate the loop input
or button that corresponds to this zone.
We recommend that you confirm the programming of every
transmitter before proceeding to the next zone.