Vista de pagina 86
17–1
SECTION 17
Output Device Programming
(
80 Menu Mode)
••••••••••••••••••••••••••••••••••••••••••••••••••
In This Section
Programming Options Defined
Programming Output Relays and Powerline
Carrier Devices
••••••••••••••••••••••••••••••••••••••••••••••••••
Programming Options Defined
The following definitions will help you understand the programming of output devices when
using
80 and
81 modes. The options used to start and stop these devices are described
below, followed by the actual screen prompts and available entries.
Relays and output devices are not recommended for life safety applications.
The letter(s) in parentheses after each function described below, such as (A) after ACTION,
are those that appear in the various summary displays of programmed data during
programming.
ACTION (A) The ACTION of the device is how the device responds when it is activated
by the Start programming. There are four different choices of actions:
Close for 2 Seconds (Relay is energized for 2-seconds and then reset).
Stay closed (Relay is energized until de-energized by another event).
1 second On/Off (Relay is alternately energized and de-energized for 1-
second at a time until this action is totally stopped by another event).
No Response (Relay is not being used).
START (STT) The START programming determines when and under what conditions the
device is activated. The following Start options are available:
Start
by Event
1.
Event
(EV) is the condition (alarm, fault, trouble) that must occur to a
zone or group of zones (a zone list) in order to activate the device. These
conditions apply only when a zone list is used. The different choices for
Event are listed below.
• ALARM......... Relay activates upon any alarm in an assigned zone in
the zone list.
• FAULT.......... Relay activates upon any opening or short in an assigned
zone in the zone list.
• TROUBLE .... Relay activates upon any trouble condition in an assigned
zone in the zone list.
• NOT USED... Relay action is not dependent upon one of the above
events.