one armed period.
The communicator will transmit a restoral message
when the zone is restored (less than 1 second).
Type 10. INTERIOR DELAY ZONE: This type of zone will always have Entry
Delay #1 and Exit Delay #1. This zone is not enabled after arming
until termination of the programmed Exit Delay #1.
If this zone is
faulted, three beeps will be emitted by the Console.
If the security
code + OFF is not entered before termination of the programmed Entry
Delay #1, an alarm will be initiated.
A system-wide programmed nwnber
of alarm reports for this zone will be allowed to be transmitted
(swinger suppression) by the ccinmunicator in one armed period. The
communicator will transmit a restoral message when the zone is
restored for a time greater than its physical response time (less than
1 second).
During the disarmed state, a faulted zone will result in a “DISARMED—
Press * to show faults” display (5137) or aNOT READY display (4137).
Subsequent depression of the * key will
and/or numbers of the faulted zones to be
communicator reports will be initiated.
cause all the descriptors
sequentially displayed. No
TABLE A. ZONE ASSIGNMENTS
A zone type must be assigned to each physical zone in use. For convenience, the
following chart has been prwided for checking off selections made.
I
PHYSICAL ZONES
I
ZONE TYPE
1 2 3 4 5 6 7 8
1. ENTRY/EXIT, Delay #1
(Burglary)
2. ENTRY/EXIT, Delay #2
(Burglary)
3. PERIMETER (Burglary)
4. INTERIOR, FOLLOWER
(Burglary)
5. TROUBLE BY DAY/ALARM
BY NIGHT (Burgtity)
6. 24-HOUR SILENT
[
I
7. 24-HOUR AUDIBLE
8. 24-HOUR AUXILIARY
9. FIRE ZONE*
10. INTERIOR, DELAY
(Burglary)
v
I
**
1,
* Physical Zone 9 cannot be used for Fire.
** Available when 4152LM and 4208 Zone Expander used.