PROGRAMMING ZONE DESCRIPTIONS FOR DISPLAY ON THE 5137 CONSOLE
An appropriate English language description/location for each protection zone
can be programmed into the system.
Each description may be composed of a
combination of words (up to a maximum of 3) that can be selected from a
vocabulary of approximately 220 words stored in memory (a complete list of all
words in this vocabulary is provided in Table E. In addition, up to 5
~!custmll words maY
installer-defined be added to those presently in memory.
Thus, when an alarm or trouble occurs in a zone, an appropriate description for
the location of that zone will be displayed at the security control.
Programming Procedure:
1.
2.
3.
4.
5.
6.
7.
8.
9.
Enter programming mode as described previously.
Key S3. The following will be displayed: * ZN ??
To select zone 1, key *O1 (key *O2 for zone 2, *O3 for zone 3 etc.). The
following will be displayed: *ZNOIA
Note that the first letter of the alphabet appears after the zone nunber.
The zone number is automatically included with the proposed description.
Select the first letter of the desired description (note that “A” is
already displayed). Use key [3] to advance through the alphabet and key [11
to go backward. For example,
assume the desired description for zone 1 is
BACK DOOR. press key [3] repeatedly (or hold down the key) until “B”
appears,
then press key [6]. Pressing key [6] will display the first
available word beginning with B. Repeatedly press key [3] to advance
through the available words until the word BA(lCis displayed.
For selection of the second word (DOOR), press key [6].
!!Allwfil now be
displayed again after the first word selected .
press key [3] until the
desired first letter of the second word appears (in this example, “D”).
Then press key [6] to display the first available word beginning with “D”.
Press key 3 repeatedly until the desired word (DOOR) appears.
If you wish to add a third word (provided there is sufficient space for it
in the display),
repeat step 6 for that word.
When all desired words have been entered,
press key [8] to store the
descriptor in memory.
To review the zone descriptions (and/or edit), key # plus zone nunber
(e.g., #01).
10.
To exit the zone description mode, key *9.