To disable Restore reports, program all locations in Addresses *69 - 71 as O.
1234
ZONE TTPEs 1-4
*69
[1[1[1[1
(See Address *O2 for Response
RESTORE REPORT types).
ENABLE
COMMENTS: Enables Restore reporting for individual
zone types. Enter 1 to select restore reporting
for the zone type; enter O to inhibit restore
reports.
ZONE TYPHS 5-8
*70
RESTORE REPORT
ENABLE
5678
[1[1[1[1
(See Address *O2 for Response
types) .
COMMENTS:
Enables Restore reporting for
individual zone types.
Enter 1 to select Restore
reporting for the Zone Type; enter O to inhibit
Restore reports.
9 10
ZONE
TYPES 9
*71
[ 1[ 1 (See Address *o2 for Response types)
AND 10 RESTORE
REPORT ENABLE
COMMENTS: Enables Restore reporting for
individual zone types. Enter 1 to select Restore
reporting for the Zone Type; enter O to inhibit
restore reports.
INTRODUCTIONTO FIELD ADDRESSES 72–81
In order to make it easier for an installer to understand expanded zone
reporting, an explanation and an illustrative example are given first.
Bearing in mind that a 2 digit reporting code is utilized, let us discuss how
zones 1-17, Duress, Zone Expander Supervisory, and the 3 keypad panics (1 & *, 3
& #, and * & #) can be coded.
The recurring theme of the following information
is that the leading digit represents the type of event being reported and the
second digit identifies the zone within that type.
NOTES :
1.
WO digit entries are required because hexadecimal entries are allowed (O-
9, B-F) = (00-15) for fields 72-81.
2. Users of the Ademco CAPS Automation System are cautioned not to assign 78
or 8C for any report,
as these codes are reserved.
3.
If Ademco High Speed Format is selected in either Addresses *46 or *48 and
the 4+2 Expanded Zone Format is selected in Address *53, a very fast 4+2
Format is created that uses DTMF (TouchTone) signaling instead of pulses.
Actually, 9 digits are transmitted but only the 4+2 portion of the message
is wer seen on the central station receiver’s display or printer.
This
High Speed 4+2 format is currently only compatible with Ademco No.
685
Digital Receiver operating with Revision 4.3 software or higher and has a
message transmission time of well under 5 seconds.
49