The detailed operation of the functions
described below is covered in the
Installation Instructions for the No.
695-30XT Program Cartridge and for the
4130PC Download Software Diskette.
To Read List of Faulted Sensors
To Read List of Bypassed Sensors
To Read 10-Day Alarm History Log
To Read 10-Day Trouble History Log
To Read List of Sensors Currently in Alarm
To Read List of Sensors Currently in Trouble
Remote Communication Specifications:
.
Program Download Time
- 1 minute for a complete program
.
Typical Total Time Including Call Up/Call-Back - 3-4 minutes.
Remote Coenmand/Progranming Advisory Notes:
.
Alarm and Trouble Reporting are disabled during the time that the system
and the central station are linked to each other for the described
functions,
following a valid exchange of codes.
.
Keypad entries are ignored during the same time interval cited above.
. Should an alarm transpire during the remote program/control interval, the
system would not respond to the alarm condition until the raote mode was
ended.
The local zones and the Nos. 4190WH, 4192, 4192SD, 4194WH, 4196,
4208 and 4275 all store their fault conditions until they are read by the
Control. As such,
alarm conditions fran the local and expansion zones
would not be missed, only delayed.
.
A copy of the progrsm downloaded may be produced from either the No. 699
Intelligent Programmer
or the IBM PC compatible computer,
using those
products! internal report generators,
when an optional printer is
connected.
ZONE TYPES AVAILABLE FOR SELECTION
For
1.
2.
3.
4.
each zone used, one of the following zone types must be selected:
Entry/Exit Burglary (Delay #l). Assigned to sensors on doors through which
entry and exit will normally take place when the system is armed.
Entry/Exit Burglary (Delay #2). May be set for different delay than above.
For use with sensors on overhead garage doors, etc., where longer delay is
needed to reach the keypad in the main portion of the house or building,
and more delay is needed to =it the premises.
Perimeter Burglary. Normally assigned to all sensors on exterior doors and
windows requiring instant alarm.
Interior, Follower.
Delayed alarm only if the Entry/Exit zone is faulted
first; otherwise, produces an instant alarm.
Assigned to zone covering an
area such as a foyer or lobby through which one must pass upon entry to
reach the keypad to disarm the system.
Designed to provide instant
intrusion alarm in the event an intruder hides on the premises prior to the
system being armed or gains access to the premises through an unprotected
area.