SPECIFIC ADDRESS PROGRAMMING INSTRUCTIONS
FUNCTION ADDRESS
INSTALLER CODE
*()()
MASTER SEQJRITY
*01
CODE
ASSIGN RESPONSE
*02
TYPE FOR ZONES
1 -8
[1[1[1[1
COMMENT S :
This 4-digit (O-9) code reserved for
installation company use. Only active if openings
and closings are enabled for User #1 (in Address
*52).
This is the only code that can be used to
enter the Program mode from the console. Cannot be
used to enter secondary codes. This code may not
be used if programming mode is exited by a ~8.
[1[1[1[1
COMMENTS: Enter 4 digits, O - 9 (entry of all 4 is
mandatory). Use of a “9” in last position inhibits
the Ambush feature.
[][]Zonel
[][]Zone2
[][]Zone3
[][1 Zone4
[][1 Zone5
[1[1 Zone6
[][]Zone7*
[][]Zone8
COMMENTS: Enter 2 digits, 00 - 10 in each field
(use one of the response types below).
ASSIGN RESPONSE
*O3
TYPES FOR ZONES
9-16
* If Zone 7 is to be
operation, 10 must
type.
00 =
01 =
02 =
03 =
04 =
05 =
06 =
07 =
08 =
09 =
10 =
1[1[1
2[1[1
3[1[1
4[1[1
511[1
6[1[1
7[1[1
8[1[1
Assign for
ENTRY/EXIT
ENTRY/EXIT
PERIMETER,
used for Keyswitch Arm/Disarm
be entered as its response
unused zones
(Delay #l), Burglary
(Delay #2), Burglary
Burglary
INTERIOR, FOLLOWER, Burglary
TROUBLE BY DAY/ALARM BY NIGHT, Burglary
24-HOUR SILENT
24-HOUR AUDIBLE
24-HOUR AUXILIARY
FIRE
INTERIOR, DELAY, Burglary
Zone 9
Zone 10
Zone 11
Zone 12
Zone 13
Zone 14
Zone 15
Zone 16
COMMENTS:
Enter 2-digit
response types (see
Address *O2 for types)
31