FUNCTION PROCEDURE
ENTER PROGRAMMING MODE: 1.
POWER UP, then depress * and # simultaneously
within 30 seconds of powering up.
OR
2. Initially, Key:
4+l+4+Oplus~DE key+ 0+
o.
OR
3.
After Installer Code is programmed, key: Inst&l.ler
Code + CODE key + O + O.
Notes: User #1 (installer) must be enabled (in
Address 52) if ~pe 3 method of entry is to
be used.
Type 3 method of re-entry to the programming
mode is inhibited if the programming mode is
exited via use of =8.
Type 1 method of entry can always be used,
unless console programming has been locked
out by the remote downloader.
EXIT PROGWING MODE:
*9 (always allows re-entry to programming mode via
Type 3 entry method above), unless console
programming has been locked out by the remote
downloader) .
*8 (inhibits re-entry to programming mode via Type 3
entry method).
Note: When the programming mode is exited, a I-
minute set-up period must elapse before the
system can properly function.
ADVANCE TO FIELD:
PRCXGRAMFIELD:
ERASE FIELDS:
READ FIELD:
RESTORE FACTORY
PROGRAM SETTINGS:
EITCERZONE DESCRIP-
TION AND INSTALLER
MESSAGE PROGRAMMING
MODE :
SPECIAL MESSAGES
* + ADDRESS (e,go, 01, 1(J,21.,etc.),
* + ADDRESS, followed by data entries.
* + ADDRESS + *
(ody applies to Addresses 31 thru 34).
# + ADDRESS
*7 (see Factory Programming Table).
*3 (only relwent if 5137 Console is being used).
OC = OPEN CIRCUIT (no communication between the Console and the Control).
FC = FIELD CODE ERROR (program entry mistake, re-enter the data).
23