Vista de pagina 58
3.
4.
5.
6.
Note 3.
In the TEST mode, no reports will be sent to the central station.
Also, the externsl sounder (if used) will not be activated.
Door and windws: Open and close each protected door and window in turn.
Each action should produce three beeps from the Console. The descriptor for
each protection zone will appear on the Console display.
Motion detectors: Walk in front of any interior motion detectors (if used).
Listen for three beeps when the detector senses movement.
While it is
activated, its descriptor will remain displayed on the Console.
Smoke detectors: Follow the test procedure provided by the manufacturer of
each smoke detector to ensure that all detectors are operational and are
functioning properly. Note:
A 2-wire smoke detector display will not clear
until the Test mode is exited.
To turn off the TEST mode,
enter the security code and press the OFF key.
A message will be sent to the central station during the following tests. Notify
the central station that a test will be in progress.
NOTE:
A display of ‘C@lM. FAILURE” (5137) or FC (4137) indicates a failure to
communicate (no Kissoff by the receiver at the central station after
the maximum number of transmission attempts is tried).
7. Arm the system and fault one or more zones.
Silence alarm sounder(s) each
time by entering the code and pressing OFF. Check Entry/Exit delay zones.
8.
Check the keypad-initiated alarms by simultaneously pressing the Panic keys
(* and #, 1 and *, and/or 3 and #).
If the system has been programmed for
audible emergency, the console will emit a loud, steady alarm sound, and
ALARM and a descriptor will be displayed for
* and # (if 1 and * are
pressed, a different descriptor will be displayed; if 3 and # are pressed,
its descriptor will be displayed).
Silence the alarm by entering the
security code and pressing OFF.
If the system has been programmed for silent emergency, there will be no
audible alarms or displays,
but a report will be sent to the central
station.
9.
Notify the central station that all tests are finished, and verify results
with them.
5137
LCD Viewing Angle Adjustment:
Insert the end of the small, key-shaped tool (supplied) into the small hole to
the left of the console display window (the adjustment screw is recessed in this
hole). Turn the adjustment screw to the left or right until optimum viewing is
achieved. Be sure to take the height of the users into account when making this
adjustment.