5.
6.
7.
8.
9.
10.
Trouble by Day/Alarm by night.
Can be assigned to a zone which contains a
foil-protected door or window (such as in a store),
or to a zone covering a
‘sensitive”
area such as a stock rocn, drug supply roan, etc., or other
controlled access area where immediate notification of an entry is desired.
During the disarmed state (day),
the system will provide latched Console
annunciation (and central station report,
if desired) of openings or
troubles (such as sensor malfunctions or foil breaks).
During the armed
state (night), violations will initiate an alarm.
24-hour Silent Alarm. This type generally assigned to a zone containing an
Emergency button
that is designed to
initiate an alarm report
to the
Central Station,
but which produces no local displays or alarm sounds.
24-hour Audible Alarm. This type also assigned to a zone containing an
~ergency button, but which will initiate an audible alarm in addition to
an alarm report to the Central Station.
24-hour Auxiliary Alarm (Console sounder only). This type assigned to a
zone containing a button for use in personal emergencies, or to a zone
containing monitoring devices such as water sensors, temperature sensors,
etc. Designed to initiate an alarm report to the Central Station and only
provides Console alarm sounds and alarm displays.
Supervised Fire (alarm on short/trouble on open).
Interior that always has Entry/Exit Delay #1 (except that Entry Delay is
suppressed in the-INSTANT mode).
This-type typically assigned to an
interior zone containing a PIR that covers an area through which the user
must pass to reach the Console for disarming purposes
first entering).
(whether inside or
Ideal for an area such as an apartment entrance foyer in
which the only Console is located.
FONCl?IONAL DESCRIPTION OF ZONE TYPES
The following is a description of the various zone types available which must be
selected for each physical zone. You may wish to use Table A at the end of this
description to record your selections.
Type 1.
BURGLARY ENTRY/EZIT (DELAY #l):
This zone type is not enabled after
arming until termination of the programmed Exit Delay #1. Upon entry,
the Console will emit 3 short beeps as a warning that the system must
be disarmed.
If the security code
+ OFF is not entered before
termination of the programmed Entry Delay Ill, an alarm will be
initiated at the built-in sounder, and an external alarm and latched
LCD display will be present. A system-wide programmed nunber of
alarm reports for this zone will be allowed to be transmitted (swinger
suppression) in one armed period.
Restoral.swill be sent when the zone
is restored for a time greater than its physical response time (less
than 1 second).
During the disarmed state, a faulted zone will result in a “DISARMED—
Press * to show faults” display (5137) or a NOT READY display (4137).
Subsequent depression
of the * key will cause all the descriptors
and/or numbers of the faulted zones to be sequentially displayed. No
communicator reports will be initiated.
me 2. BURGLARY ENTRY/EZIT (DELAY #2):
This zone type is not enabled after
arming until termination of the programmed Exit Delay #2.
Upon entry,
the console will simply emit 3 short
beeps as a warning that the
system must be disarmed.
If the security code + OFF is not entered
before termination of the programmed Entry Delay #2, an alarm will be
initiated at the built-in sounder, and an =tern~ aJ-arm and latched
6