ZONE EXPANSION
Zone expansion to an additional 8 zones is achieved by connection to No. 4208
Eight-Zone Expander by a single pair of wires providing both power and
signaling. Each of the 8 zones on the No.
4208 can be programmed from the
various types described in this manual that are available for use on the basic 9
zones,
with one exception.
There is no ability to support 2 wire smoke
detectors on any of the zones available in the No. 4208 Zone Expander.
The No.
4208 Zone Expander may be located near the No. 4140 or remotd.y from it. The
two wire run to it should utilize twisted pair wiring and should not be run in
close proximity to protected praises interccm wiring [at least a 3-inch (8 cm)
separation] .
For the maximum wiring run permissible to the zone expander for
various’ wiring gauges, see the Specifications Section relative to the No.
4208
Zone Expander later in this manual.
IMPORTANT :
In order to utilize the No. 4208 to obtain zones 10-17, this
product’s DIP switches must be set as follows:
0000
(as if set for sensor nunbers 113-120, as
cited in the instructions for the No. 4208)
Installation instructions for the wiring connections to the No. 4208 are
provided in a subsequent section entitled “WIRING TO No. 4208”.
4-DIGIT SECURITY CODES
Installer Code:
The instsller programs the Installer Code initially as part of the programming
procedure (see
mprogrming ‘he
Security Control”).
In this system, the
installer is considered to be user #1.
The installer code permits re-entry into
the programming mode (unless
*98 has been previously used to exit
the
programming mode) and also allows access
to the normal functions of the systen.
During initial programming, the installer also programs the Master security code
into the system. Open/Close reporting must be enabled for User # 1 for this code
to be operational.
[1[1[1[1
Installer Code (User #l), assigned during programming.
Installer exits programming mode with:
W39 (allows re-entry into programming mode with installer code).
or
*8 (does not allow re-entry to programming mode unless system is
first powered
down and then repowered). Installer code is
disabled when this exit is used.
Master Security Code:
The Master security code
can be used to assign up to thirteen secondary codes
(to users #3-#15): it can also be used to remove all secondary codes from the
system (individually).
The person to whom the Master code is assigned is
considered to be user #2.
In some applications
(canmercial installations, for
example), user #2 (with Master code) will be the main user of the systen (see
Application 1 on a following page).
In other applications (such as in an
apartment complex, for example),
user #2 (with Master code) may not be the
actual end user of the system (see Application 2 on a f~lowing Page).