3. Key 00. The following will appear: * ED ??
40 Press the 5 key.
The following will appear:
****DI~****
READY TO ARM
A cursor will be present on the extreme left of the first line (over the
first “star”).
The 6 key is used to move the cursor to the right and the 4
key to move the cursor to the left.
Key 7 may be used to to insert spaces or
erase existing characters.
5.
For example,
to replace
READY TO ARM with the message SERVICE:424-0177,
proceed as follows:
Press the 6 key to move the cursor to the right, and continue until the
cursor is positioned over the first location on the second line.
Press the 3 key to advance through the alphabet to the first desired
character (in this case, “S”).
Use the 1 key to go backward, when
necessary. When the desired character is reached, press 6. The cursor will
then move to the next position,
ready for entry of the next character (in
this
example,
lfEtl).
When the cursor reaches a position over an existing
character, pressing the 3 or 1 key will advance or back up frcm that
character in the alphabet.
Proceed in this manner until all characters in
the message have been entered.
6. To store this new display message in memory, press the 8 key.
7.
Press the * key to return to the *
ZN ?? display. To confirm that the new
message has been stored in memory, press 00 and then press key 5. The new
message should be displayed.
8. Key *99 to exit the descriptor/programming mode.
TESTING THE SYSTEM
After installation is completed,
the Security System should be carefully tested.
1.
With the System in the disarmed state, check that all zones are intact. If
DISARMED -
Press * to shuw faults (5137) or NOT READY (4137) is displayed,
press the * key to display the descriptors of the faulted zone(s). Restore
faulted zone(s) if necessary,
so that
****DISARMED***READY TO ARM (5137) or
READY (4137) is displayed.
2. Enter the security code and press the TEST key.
The external sounder (if
used) should sound for 3 seconds and then turn off (the system is operating
on the back–up battery only at this time).
Note 1.
The system will not enter the TEST mode if the battery voltage is
too low,
if the battery is not connected, or if any communication
messages are waiting to be transmitted.
Note
2.
As a reminder that the system is in the TEST mode, the Console
will sound a single beep at 15-second intervals if no protection
zones are violated.