EXIT DELAY #1
*1()
[1[1
COMMENTS: Defines the time delay period after the
system arming code is keyed when zone to which
this delay has been assigned will arm (UL 1023
Household Burglary usage permits a maximum of 60
seconds) . Is also the exit delay time allocated
to the Interior zones (both Follower and Delay
types) .
Enter 00 – 15. Multiply by 15 seconds to determine
time delay (O
- 225 seconds available).
ENTRY DELAY #2
*11
[1[1
COMMENTS: Defines the time period between a fault
occurring in a zone to which Entry Delay #2 has
been assigned and
the time when the alarm will
sound.
(UL 1023 Household Burglary usage permits a
maximum of 45 seconds).
Must be set for longer
period than Entry Delay #1 (in Address * 09).
Enter 00 -
15. Multiply by 15 seconds to determine
time delay (O - 225 seconds available).
EXIT DELAY #2
*12
[1[1
COMMENTS: Defines the time delay period after the
system arming code is keyed when zone to which
this delay has been assigned will arm.
(UL 1023
Household Burglary usage permits a maximum of 60
seconds).
Must be set for longer period than Exit Delay #1
(in Address *1O).
Enter 00 - 15. Multiply by 15 seconds to determine
time delay (O - 225 seconds available).
ALARM SOUNDER
*13
[1[1
DURATION
COMMENTS: Defines the length of time an external
or the console’s alarm sounder will sound for all
audible alarms (UL 1023 Household Burglary usage
requires a minimum of 4 minutes).
Enter 01 - 15. Multiply by 2 minutes to determine
sounder duration.
ALARM SOUNDER
*14
SELECTION
KEYSWITCH ARM/
*15
DISARM ENABLE
[01
COMMENTS:
Enter O for DC drive to operate the
alarm relay. Do not enter 1.
[1
COMMENTS: Requires the use of zone 7 wired loop
(zone 7 no longer
available as protection zone
when used for keyswitch operation).
Enter 1 for keyswitch enable; otherwise, enter O.
NOTE: 10 must have been entered for Zone 7 in
Address *02.
Reports openings/closing by user #7
if reporting is enabled in Address *52.