ALARM SOUNDER
DURATION
(01-S times 2 minutes)
CONFIRMATION OF
ARMING DING ENABLE
(O/l 1
AC POWER LOSS
SOUNDING
(011)
CONTROL ALARM
SOUNDER DISABLE
(O/l 1
DISABLE FIRE TIME-OUT
(011)
CONTROL ALARM
SOUND SELECTION
(O/l )
PROGRAbfMING THE SYSTEM
83
- F. SOUNDER OPTIoNS -
‘13
‘18
‘17
va
l
21
‘26
-II
lo14)
COMMENTS: Enter the length of time an external sounder or the
console’s sounder will sound for ail audible alarms (multiply entry Ol-
15 by 2 minutes for actual duration)
I
El
COMMENTS: Enter 1 to enable haff second external alarm sounding
(‘ding’) at either the end of exit delay #l , if OpenlCiOSe reporting is
not selected, or when kissoff is received from central station if
Open/Close reporting is programmed.
Enter 0 to disable the “ding”.
I
El
COMMENTS: Enter
1
if sounding at the console (rapid beeping)
when AC power is lost is desired. Enter 0 if no AC power loss
sounding is desired.
I
I
COMMENTS: Must be zero for 4140XM. For 4130XM1513OXM. enter
1 to disable internal alarm sounder. Does not apply to remote
consoles.
I
I
COMMENTS: Enter 1 to disable (no timeout) the sounder time-out
feature for any zone designated as a fire zone so that fire sounding
continues until the system is reset
I
0
lol
COMMENTS: For 4130XM/5130XM, enter 1 for a sweeping sound
at the Control upon alarm. Enter 0 for steady sound. This field does
not apply to the 4140XM nor to the 413715137 consoles.