ADEMCO 5130XM Manual de instrucciones Pagina 127

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 159
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 126
126
SPECIFICATIONS
5706 SMOKE DETECTOR/TRANSMITTER:
1.
Physical:
Diameter: 6-l/2” (165mm)
Height:
1 -l/l 6’ (27mm)
2. Electrical:
Voltage:
9V Lithium type battery: Ademco No. 465, Kodak USVL
9V Alkaline type battery: Ademco No. 464. Eveready 522, Duracell MN1 604.
Battery should be changed at least annually or within 30 days after a BAT message indication,
whichever occurs sooner. Battery change of Lithium battery can be at three year intervals for
non-UL usages.
Range:
200 ft nominal (6Om), indoors.
Addressability: 5 bit house code: 31 code combinations
3 bit device code: 8 code combinations (48-55).
5701 EMERGENCY (PANIC) TRANSMITTER:
1. Physical:
Width: 2-9116’
wfm
Height:
4-13116. (122mm)
Thickness:
l-5116
(24mm)
2. Electrical:
Voltage:
9V Ltthium type battery: Ademco No. 465, Kodak USVL
9V Alkaline type battery: Ademco No. 464. Eveready 522, Duracell MN1604.
;-.
Battery should be changed at least annually or within 30 days after a BAT message indication,
whichever occurs sooner. Battery change of Lithium battery can be at five year intervals for
non-UL usages.
Range:
200 ft. nominal (60m), indoor.
Addressability:
5 bit house code: 31 code combinations
1 bit device code: 2 code combinations (62 or 63).
ADEbKO’r VISTA XbJ SERIES TECENICAI. REFERENCE blANVAI.
WWW.DIYALARMFORUM.COM
Vista de pagina 126
1 2 ... 122 123 124 125 126 127 128 129 130 131 132 ... 158 159

Comentarios a estos manuales

Sin comentarios