SECTION X
PROGRAMMING THE SYSTEM
SECTION X
71
- A. GENERAL INFORMATION -
EEROM MEMORY
LOCAL/REMOTE .
PROGRAMMING
PRE-PROGRAMMED
COMMUNICATION
0
FORMATS
TWO SETS OF
PROGRAMMING FIELDS
System programming options are stored in non-removable, electrically
erasable, non-volatile EEROM memory (removal of power wlil not resul In the
bss of the Information). Consequently, lt is possible to program the system at
any time - even at the install&s premises prior to the actual installation. Simply
apply power temporarily to the Control and then program the unit as desired.
These options must be programmed for the particular installation to establish
its
specific alarm and reporting features.
The Control can be programmed from the keypad or from a computer terminal
using the VISTA XM Downloading software (see DOWNLOADING section).
When programming from the 5130XMI5137 consoles, prompts for each field
description (only field number will be displayed on the 4130XMHl37
consoles) and field number will be displayed; also, each entry is displayed as
it is keyed in. After programming, values that have been entered in each field
can be reviewed and, if neccesssaty. modified.
The system is shipped with a set of standard preprogrammed values that are
designed to meet the needs of many installations. However, these can be
altered by the installer to suit the specific needs of a particular installation or
installatiin company. In addition, four sets of pm-programmed communicator
defautts are available which may be loaded by the Installer. each set designed
for a specific communication format (see SUMMARY OF CONNECTIONS
section for lit of values). These, too, may be altered to suit the needs of a
particular installation.
IMPORTANT!: If any of these communication preprogrammed formats are
to be used, they must be programmed (using the appropriate command)
before any other field programming is performed.
The programming fields are grouped into two sets of add&es. The first set
of fields includes addresses ‘00 -
l
90, and is accessible as soon as
programming mode is entered. When in the first set of fields, the
5130XMI5137 consoles will display ‘PROGRAM MODE’ and will put a
hyphen in front of the field address. while the 4130XMI4137 consoles will
simply display the fiild address.
The second set of field addresses is accessed by pressing ‘94. while in
programming mode, and are referred to In this document by a -1. in front of
the address (ex. 1’39). The alpha consoles (513OXM15137) will indicate this
by displaying the words “ALT PROGRAM MODE* on the top line of the
display, and displaying a .l’ in front of the field address (i.e. field ‘32 of the
second set of addresses is displayed as 132). The 4130XMI4137 consoles
will display the word CHECK when the second set of addresses is accessed.
The second set of fields includes addresses 1’00 - 1’49. To return to the
first set of fields, press ‘99. noting that the alpha consoles display the words
‘PROGRAM MODE”. and the word CHECK disappears from the 4130XMI
4137 displays.
ADEMCO’s VISTA XM SERIES TECHNICAL REFERENCE MANUAL
WWW.DIYALARMFORUM.COM